VC600 Clamp-on Ultrasonic Gas Flow Sensor

Measure gas consumption without cutting a single pipe with the CS Instruments VC 600. Expertly manufactured by CS Instruments, this high-performance non-invasive clamp-on flow sensor tracks compressed air and industrial gases from the outside. Furthermore, its ultra-safe clamp architecture eliminates installation downtime, contamination threats, and costly pressure drops across your entire production plant. Watch Video

PDF Datasheet

SKU: VC600 Categories: , ,
Description

Description

Key Features & Benefits of the VC600 non-intrusive Clamp-on Ultrasonic Gas Flow Sensor

  • Zero-Interference Clamp Design: Mounts externally onto live pipes with zero drilling or welding, maintaining complete process safety.
  • Thin-Walled Pipe Compatibility: Leverages proprietary signal evaluation to monitor thin-walled stainless steel lines (DIN EN 10357) down to 1.5 mm thickness.
  • Integrated Touchscreen Interface: Displays live flow profiles directly on-site while supporting swift commissioning through simple menu wizards.
  • Smart App & Wireless Telemetry: Connects via Bluetooth to the free CS SensorApp for easy configuration, parameterization, and deep data analysis.

Working Principle

The VC 600 operates on an advanced ultrasonic time-of-flight difference measurement technique. The system straps two precision ultrasonic crystals (operating as paired transmitters and receivers) onto the outer pipe skin. These sensors alternate emitting sound waves diagonally through the pipe walls and moving gas stream, one travelling in the direction of flow and the other against it. Because the gas velocity accelerates the sound transit time downstream and delays it upstream, a distinct mathematical time-of-flight gap emerges. State-of-the-art algorithms process this time difference online to compute the exact volumetric flow rate in real time.

Advantages

  • 90% Time Savings on Setup: Installs in just a few moments using a standard screwdriver and an innovative quick-release clamping system.
  • Zero Energy & Pressure Loss: Keeps your fluid networks completely unconstricted, preventing the costly pressure drops or leakage risks common with inline meters.
  • Unparalleled Flow Dynamics: Captures minor network leaks and heavy-velocity flows alike with an extended measurement scope reaching up to 25 m/s.
  • Long-Term Ring Buffer Memory: Features an integrated 50 MB data logger to archive consumption profile and leakage history data over two full years.

Product Types & Ordering Codes

The VC 600 system is highly adaptable. It lets users configure the modular hardware and software paths to fit the exact structural constraints of their process lines:

  • Quick-Clamping System Sizes (A20 to A100): Tailored across ten physical model sizes to clamp cleanly onto external pipe diameters ranging from Ø 25 mm up to Ø 90 mm.
  • Wall Thickness Tiers (B1 & B2): Calibrated for thin-walled lines from 1.5 to 2.2 mm (B1) or heavy-duty schedule pipes from 2.2 to 5.0 mm (B2).
  • Calibration Options (D1 & D2): Gas set by its gas constant (D1) or a real gas calibration for the selected gas (D2).
  • Velocity Output Versions (F1 & F2): Scaled for standard flow dynamics up to 20 m/s (F1) or high-speed processing streams up to 25 m/s (F2).

Technical Specifications

Specification Parameter Value Details
Primary Measurement Units m³/h, l/min (at 1000 mbar, 20 °C) or Nm³/h, Nl/min (at 1013 mbar, 0 °C)
Sensor Technology Ultrasonic non-intrusive “clamp-on” time-of-flight array
Supported Media Compressed Air, Nitrogen (N2), and other industrial gases on request
Compatible Pipe Materials Stainless Steel, Carbon Steel, and Aluminium
Minimum Operating Pressure From 3.0 bar(g) upwards (No maximum pressure limitation)
Measurement Accuracy ± 1.5% of the measured value ± 0.3% of full scale
Operating Temperatures -20°C to +80°C media exposure limits
Standard System Interface 4…20 mA analogue output paired with RS 485 Modbus RTU
Advanced Bus Options IO-Link, Ethernet PoE (Modbus/TCP), M-Bus, or wireless Bluetooth
Enclosure Protection Class Polycarbonate and Aluminium housing rated to IP 65
Quick-Release Hardware Heavy-duty AISI 316L Stainless Steel clamping bracket structure

Applications

  • Semiconductor Manufacturing: Delivers high-precision flow tracking for high-purity nitrogen distribution arrays without risking particle contamination in cleanrooms.
  • Pharmaceutical Processing lines: Monitors pneumatic consumption and detects leakage non-invasively, keeping the hygienic integrity of sterile piping intact.
  • Food & Beverage Packaging: Manages industrial gas usage during active filling, capping, and blanketing stages to maintain hygienic and cost-effective production.
  • Plant Energy Management: Audits major manufacturing loops to measure local air losses and accurately balance compressor efficiency.
About CS Instruments

CS Instruments, from Germany, makes measuring instruments for compressed air and gases, and Schmierer SEA offers nine of them from Shah Alam: flow meters for consumption and compressor capacity, the LD500 and LD510 ultrasonic leak detectors with camera, and dew point, particle and oil vapour sensors for air quality. Our team helps you select the instrument and set it up.

Which CS Instruments product for which job

JobProductStated figures
Consumption in dry airVA 500, 520, 550, 570Thermal mass flow, no moving parts; up to 40 bar (selected VA 520) or 50 bar (selected VA 550)
Wet air at the compressor outletVD 500-30 to +180 °C, up to 30 bar, DN 20 to DN 600
Compressor capacity and billingCMM 500±0.5% of reading from 20 to 100% of maximum flow
Flow without cutting the pipeVC600Clamp-on ultrasonic, pipes 25 to 90 mm outside diameter
Finding leaksLD500 and LD510Leak rate and annual cost estimate per leak; LD510 adds a sensor input
Dew point and humidityFA 510, FL 510Pressure dew point after the dryer; 0 to 100% RH
ParticlesPC400From 0.1 µm or 0.3 µm, three size channels
Oil vapourOil Check5000.001 to 5 mg/m³ at 3 to 9 bar
Air quality as one systemCompressed Air Quality MonitoringParticle, moisture and oil sensors on one interface

Where to start

  • High energy bill: measure consumption with a VA sensor, then find the leaks with the LD500.
  • Compressor performance in doubt: the CMM 500 is built as a reference meter for free air delivery.
  • Air quality requirements: ISO 8573-1 classes air by particles, water and oil; the PC400, FA 510 and Oil Check500 measure each.

All CS Instruments products and the compact gas flow sensors we offer are on the compressed air flow meter page. Tell us the pipe size, pressure and what you need to know, and send an enquiry.