The systec Controls deltawaveSUF Gas Ultrasonic Flow Meter measures gas flow using ultrasonic transit-time technology. It combines multipath ultrasonic measurement with integrated pressure and temperature sensors to determine operating volume flow and compensated standard volume flow.

Moreover, its design requires only short inlet pipe sections and creates very little pressure loss. With no moving parts, it also reduces mechanical wear and routine maintenance. Therefore, the deltawaveSUF is a practical solution for industrial gas monitoring, consumption measurement and gas supply applications.

SKU: Deltawave SUV Categories: ,
Description

Description

Models and Configurations

The deltawaveSUF series is available in several nominal pipe sizes to suit different gas flow requirements.

 

Model Size Nominal Diameter Measuring Range
DN25 1 inch 0.5–50 m³/h
DN32 1¼ inch 0.8–80 m³/h
DN40 1½ inch 1.2–120 m³/h
DN50 2 inches 2–200 m³/h
DN80 3 inches 5–500 m³/h
DN100 4 inches 8–800 m³/h
DN150 6 inches 18–1,800 m³/h
DN200 8 inches 30–3,000 m³/h
DN250 10 inches 48–4,800 m³/h
DN300 12 inches 70–7,000 m³/h

Power and Communication Options

  • Battery-powered operation: Suitable for locations without a continuous external power supply.
  • External power supply: Supports 5–26 V DC.
  • Pulse outputs: High-frequency and low-frequency outputs for volume counting.
  • Analog output: Optional passive 4–20 mA output for compensated flow.
  • Digital communication: Optional RS485, Modbus RTU and NB-IoT.
  • Integrated display: Shows flow rate, total volume, temperature, pressure, battery status and alarms.

Key Specifications

  • Manufacturer: systec Controls
  • Model: deltawaveSUF
  • Measurement principle: Multipath ultrasonic transit-time difference
  • Nominal pipe sizes: DN25–DN300
  • Compatible gases: Natural gas, propane, butane, LPG, air, nitrogen and other compatible gases
  • Accuracy class: Class 1.0 standard; optional Class 0.5
  • Calibrated measuring range: Up to 1:100, depending on the model
  • Lower detection limit: Up to 1:500 on suitable configurations
  • Medium temperature: −25°C to +60°C
  • Pressure rating: PN16
  • Pressure measurement: Integrated digital pressure sensor
  • Temperature measurement: Integrated digital temperature sensor
  • Pressure measurement error: Less than 0.5 kPa
  • Temperature measurement error: Less than 0.5°C
  • Pressure loss: Less than 1.0 kPa (10 mbar)
  • Power supply: Battery operation for at least four years, or external 5–26 V DC
  • Wetted materials: Aluminium, stainless steel and glass, depending on the component
  • Data storage: Hourly values for 60 days and daily values for 11 years
  • Explosion protection: ATEX II 1G Ex ia IIC T4 Ga, according to the applicable manufacturer specification

Important: Pressure and temperature limits, hazardous-area suitability, accuracy and output availability must be checked against the current datasheet and exact order code. Standard-volume compensation also depends on the configured gas and valid operating conditions.

Working Principle

The deltawaveSUF uses the ultrasonic transit-time difference method to determine gas velocity and flow.

Step 1 – Send ultrasonic signals. Ultrasonic pulses travel through the gas in both the direction of flow and against the direction of flow.

Step 2 – Measure transit times. The sound wave travels faster with the gas flow and slower against it. The meter measures the difference between the two transit times.

Step 3 – Calculate gas flow. The electronics use the transit-time difference to calculate gas velocity and volume flow through the meter.

Step 4 – Compensate for pressure and temperature. Integrated sensors measure the gas pressure and temperature. The meter uses these values to calculate compensated standard volume flow where the configured gas model and operating conditions permit.

Step 5 – Display and transmit data. The display shows flow and process information. Optional outputs allow the measured values to be transferred to a PLC, SCADA system or energy monitoring platform.

Consequently, the deltawaveSUF can measure gas consumption while accounting for changes in operating conditions, without requiring a separate volume corrector for supported configurations.

Advantages

  • High measurement accuracy: Class 1.0 is standard, with optional Class 0.5 configurations.
  • Wide measuring range: Suitable models offer calibrated rangeability up to 1:100.
  • Low pressure loss: Pressure loss remains below 10 mbar according to the published specification.
  • No moving parts: Reduces mechanical wear and routine maintenance.
  • Integrated compensation: Built-in pressure and temperature sensors support standard-volume calculations.
  • Short inlet sections: Integrated flow conditioning helps reduce installation-length requirements.
  • Flexible power supply: Battery operation supports remote installations, while external power is also available.
  • Data logging: Stored hourly and daily values support consumption analysis.
  • Industrial communication: Optional Modbus RTU, RS485, NB-IoT and 4–20 mA interfaces support system integration.

Applications

The systec Controls deltawaveSUF is suitable for:

  • Natural gas consumption measurement
  • Industrial gas supply and distribution
  • Compressed air monitoring
  • LPG flow measurement
  • Propane and butane measurement
  • Nitrogen consumption monitoring
  • Chemical processing
  • Food and beverage production
  • Industrial manufacturing
  • Energy management and gas billing applications, subject to applicable certification requirements

Conclusion

The systec Controls deltawaveSUF Gas Ultrasonic Flow Meter combines multipath ultrasonic measurement with integrated pressure and temperature sensing. It provides accurate gas flow measurement, low pressure loss and optional standard-volume compensation in a compact industrial meter.

Moreover, its broad range of pipe sizes, battery-powered option, integrated data logging and flexible communication interfaces make it suitable for industrial gas monitoring and consumption management.

About Systec Controls

Products & Features

Systec Controls from Germany specializes in Differential Pressure (DP) and Ultrasonic Transit Time flow technologies for gas and steam. Their systems are designed for extreme industrial conditions, high temperatures, high pressures, and contaminated media.

Differential Pressure Technology (Deltaflow Series):
This technology uses the proven differential pressure principle, where a primary element (like a Pitot Tube or Venturi) creates a pressure drop proportional to the flow velocity.

Ultrasonic Transit Time Technology (Deltawave Series):
This technology measures the time difference between ultrasonic signals traveling with and against the flow direction. It is virtually maintenance-free as it has no moving parts or pressure loss.

Key Benefits

  • Cost Savings: Clamp-on technology saves significantly on installation time and operating costs, as there is no need to interrupt the process.
  • Low Energy Consumption: The deltaflow system is designed to have very low pressure losses, resulting in energy savings.
  • Long-Term Reliability and Robustness: designed for longevity, robust sensors against fouling (soiling).100% Maintenance free clamp on ultrasonic systems
  • Optimized DP Technology: lowest pressure loss with high precision
  • Easy Installation and a uniform display concept for both portable and permanently mounted devices.