VD500 Flow Sensor for Wet Compressed Air

The CS Instruments VD 500 Flow Sensor measures compressed air flow directly downstream of the compressor, where the air can still contain moisture and reach elevated temperatures. It is designed to measure flow, total consumption, temperature, and pressure, making it particularly useful for compressor performance analysis and compressed air energy audits.

Unlike thermal mass flow sensors intended for dry compressed air, the VD 500 uses a differential-pressure measurement principle. Its robust design supports high flow velocities and temperatures up to 180°C. In addition, the sensor can be installed through a ½-inch ball valve under pressure, reducing the need to shut down the system for installation when the correct fittings and safety procedures are used.

Description

Description

Key Specifications

  • Manufacturer: CS Instruments
  • Model: VD 500
  • Instrument type: Flow sensor for wet compressed air
  • Measurement principle: Differential pressure
  • Measured parameters: Flow, total consumption, temperature, and pressure
  • Medium temperature: −30°C to +180°C
  • Operating pressure: Up to 30 bar, depending on configuration
  • Pipe sizes: DN 20 to DN 600, depending on version
  • Flow velocity: Measures from approximately 2 m/s; maximum range depends on configuration
  • Accuracy: Typically ±1.5% of measured value, subject to the specified range and conditions
  • Standard outputs: 4–20 mA, pulse, and RS-485 Modbus-RTU
  • Optional interfaces: Ethernet/Modbus TCP, PoE, M-Bus, or IO-Link, depending on version
  • Power supply: 18–36 VDC
  • Installation: Through a ½-inch ball valve

Working Principle

  1. Differential-pressure measurement: The probe measures dynamic pressure associated with the moving gas.
  2. Velocity calculation: The sensor uses the measured pressure difference to determine gas velocity.
  3. Flow calculation: The configured pipe diameter and gas properties are used to calculate volumetric flow.
  4. Compensation: Integrated temperature and pressure measurements help compensate for changing gas density.
  5. Output and totalisation: The sensor displays and transmits flow and consumption data through its configured interfaces.

Main Advantages

  • Suitable for moist compressed air immediately downstream of a compressor.
  • Operates at temperatures up to 180°C.
  • Handles high flow rates and fast-changing compressor loads.
  • Measures flow, total consumption, temperature, and pressure.
  • Supports compressor capacity testing and free-air-delivery (FAD) analysis.
  • Offers standard analogue, pulse, and Modbus-RTU outputs.
  • Supports installation under pressure when the correct mounting arrangement is used.

Typical Applications

  • Compressor delivery measurement
  • Free-air-delivery (FAD) analysis
  • Compressed air energy audits
  • Compressor efficiency assessment
  • Monitoring flow before downstream drying and treatment equipment

Installation Considerations

Install the VD 500 after a functioning water separator, as recommended by the manufacturer. A water separator helps remove bulk liquid water before the flow sensor. Confirm the required insertion depth, straight-run requirements, pipe diameter, operating pressure, and temperature limits for the selected configuration.

About CS Instruments

CS Instruments, from Germany, makes measuring instruments for compressed air and gases, and Schmierer SEA offers nine of them from Shah Alam: flow meters for consumption and compressor capacity, the LD500 and LD510 ultrasonic leak detectors with camera, and dew point, particle and oil vapour sensors for air quality. Our team helps you select the instrument and set it up.

Which CS Instruments product for which job

JobProductStated figures
Consumption in dry airVA 500, 520, 550, 570Thermal mass flow, no moving parts; up to 40 bar (selected VA 520) or 50 bar (selected VA 550)
Wet air at the compressor outletVD 500-30 to +180 °C, up to 30 bar, DN 20 to DN 600
Compressor capacity and billingCMM 500±0.5% of reading from 20 to 100% of maximum flow
Flow without cutting the pipeVC600Clamp-on ultrasonic, pipes 25 to 90 mm outside diameter
Finding leaksLD500 and LD510Leak rate and annual cost estimate per leak; LD510 adds a sensor input
Dew point and humidityFA 510, FL 510Pressure dew point after the dryer; 0 to 100% RH
ParticlesPC400From 0.1 µm or 0.3 µm, three size channels
Oil vapourOil Check5000.001 to 5 mg/m³ at 3 to 9 bar
Air quality as one systemCompressed Air Quality MonitoringParticle, moisture and oil sensors on one interface

Where to start

  • High energy bill: measure consumption with a VA sensor, then find the leaks with the LD500.
  • Compressor performance in doubt: the CMM 500 is built as a reference meter for free air delivery.
  • Air quality requirements: ISO 8573-1 classes air by particles, water and oil; the PC400, FA 510 and Oil Check500 measure each.

All CS Instruments products and the compact gas flow sensors we offer are on the compressed air flow meter page. Tell us the pipe size, pressure and what you need to know, and send an enquiry.