Pressure

Bourdon Tube
7 products
Boiler
2 products
Chemical
3 products
Phenolic
1 product
Differential
7 products
Capsule
3 products
Test Pressure Gauge
5 products
Contact
4 products
Diaphragm
3 products
Diaphragm Seal
1 product
Digital
2 products
Pressure Transmitter
10 products
Pressure Switch
5 products
Load and Force
11 products
Accessories
15 products
Temperature

RTD
5 products
Bimetallic
2 products
Gas Filled
2 products
Non-Replaceable Inserts
3 products
Replaceable Inserts
4 products
Ceramic Protection
7 products
Mineral Insulated
4 products
Flameproof and Intrinsically Safe
7 products
Surface and Machinery
30 products
Food and Pharma
7 products
HVAC
9 products
Acids, Alkalis, Salts
4 products
Temperature Switch
1 product
Thermowell
16 products
Indicator, Controller
8 products
Accessories
9 products
Humidity
7 products
Thermocouple
50 products
Cable Sensors
38 products
Head Sensors
9 products
High Temperature
6 products
Temperature Transmitter
6 products
Flow

Electro Magnetic
2 products
Vortex
3 products
Swirl
1 product
Ultrasonic
7 products
Coriolis Mass Flowmeter
28 products
Positive Displacement
6 products
Variable Area
1 product
Differential Pressure
7 products
Turbine
4 products
Flap
1 product
Side Glass
1 product
Thermal gas
5 products
Air Flow/Quality
11 products
Flow Switch
9 products
Flow Computer
3 products
Flow Accessories
2 products
Dosing/Batching
6 products
Level

Radar
3 products
Ultrasonic
1 product
Capacitance
7 products
Conductivity
4 products
Magnetic
1 product
Float/Buoyancy
7 products
Level Indicator
3 products
Vibrating Rod
3 products
Rotary Paddle
2 products
Hydrostatic
2 products
Optical
1 product
Level Switches
11 products
Calibration Devices

Multi Function Calibrators
2 products
Pressure Calibrators
4 products
Temperature Calibrators
6 products
Valve Testing
1 product
Calibration Software
1 product
Valves

Actuator
1 product
Ball Valves
2 products
Butterfly Valves
3 products
Gate Valves
2 products
Globe Valves
3 products
Analytical Sensors

Water Quality Sensors
16 products
Process Systems
11 products
Density and Concentration
12 products
Analytical Controller
2 products
Process Systems
Air Flow/Quality
A compressed air flow meter shows what each compressor delivers and what each line uses; flow that carries on when production stops points to leaks. Schmierer SEA offers compressed air instruments from our partner CS Instruments: thermal mass, wet-air and clamp-on flow meters, the LD500 and LD510 ultrasonic leak detectors with camera, and dew point, particle and oil vapour monitors.
Which instrument for which job
Nine CS Instruments products and two compact Müller IE sensors; the figures are the ones each product page states, so you can see which compressed air flow meter or monitor fits the task.
| Job | Product | How it measures | Stated figures |
|---|---|---|---|
| Consumption in dry air | VA 500, 520, 550, 570 | Thermal mass flow, no moving parts | Up to 40 bar (selected VA 520) or 50 bar (selected VA 550) |
| Wet air at the compressor outlet | VD 500 | Differential pressure | -30 to +180 °C, up to 30 bar, DN 20 to DN 600, typically ±1.5% of reading |
| Compressor capacity (FAD), billing | CMM 500 | Venturi differential pressure | ±0.5% of reading from 20 to 100% of maximum flow; span over 1:130; under 70 mbar loss |
| Flow without cutting the pipe | VC600 | Clamp-on ultrasonic | Pipes 25 to 90 mm outside diameter, from 3 bar(g), up to 25 m/s |
| Finding leaks | LD500 and LD510 | Ultrasound, with camera | Leak rate in L/min or CFM and annual cost estimate; LD510 adds a sensor input |
| Dew point and humidity | FA 510, FL 510, IAC 500, IAC 510 | Dew point, humidity and ambient sensors | FA 510: pressure dew point after the dryer, IP66; FL 510: 0 to 100% RH; IAC 500/510: ambient conditions around the compressor |
| Particles | PC400 | Optical laser counter | From 0.1 µm or 0.3 µm, three size channels |
| Oil vapour | Oil Check500 | Photoionisation detector | 0.001 to 5 mg/m³ at 3 to 9 bar |
| Air quality as one system | Compressed Air Quality Monitoring | Particle, moisture and oil sensors on one interface | See product page |
| Gas flow in machines and ducts | MEFS-K, MKFS | Calorimetric | MEFS-K: 2 to 2000 cm/s, G1/4 or G1/2; MKFS: gases 2 to 2000 cm/s, G1/4 or G1/2 |
How to choose a compressed air flow meter
- Before or after the dryer: hot, wet air at the compressor outlet needs the VD 500 or CMM 500; dry air in the distribution suits the VA series.
- No shutdown: the VC600 clamps onto the outside of the pipe, and the VD 500 can be fitted under pressure through a 1/2 in ball valve; the VA 550 also installs through a ball valve where its configuration permits.
- Capacity tests and billing: the CMM 500 is built as a reference meter for free air delivery and for metering dry air.
- Leak surveys: the LD500 locates and photographs each leak and estimates its rate and annual cost; choose the LD510 to read dew point, flow, pressure or temperature with the same instrument.
- Air quality: ISO 8573-1 classes air by particles, water and oil, so pair the PC400, FA 510 and Oil Check500 to monitor all three (the Oil Check500 covers oil vapour).
- Hazardous areas and other gases: VA 550 and VA 570 versions with ATEX/IECEx or DVGW approval are available, depending on version.
Tell us the pipe size, pressure and what you need to know (consumption, capacity, quality or leaks), and our team in Shah Alam will help you select the instrument and set it up: send an enquiry. See also thermal gas flow meters and ultrasonic flow meters.
To plan the measuring points for a whole plant, read how to implement a compressed air monitoring system.






