SSEA-CONDX Conductivity Sensor

SSEA-CONDX digital conductivity sensors replace traditional two-electrode designs with high-precision four-electrode technology. They eliminate polarization effects, feature built-in automatic temperature compensation, and use an RS485 MODBUS protocol interface for simultaneous output of conductivity, salinity, total dissolved solids (TDS), and temperature. Housed in IP68 corrosion-resistant bodies, they are ideal for long-term deployment in surface water, wastewater, and aquaculture.

SKU: SSEA-CONDX Categories: ,
Description

Description

Schmierer SEA Turbidity Sensors are designed for online water quality monitoring by measuring the cloudiness of water caused by suspended particles, such as sediment, microorganisms, organic matter, and other contaminants. Turbidity is an important indicator of water quality because high particle concentrations can reduce light penetration, affect aquatic ecosystems, and indicate potential contamination.

Turbidity is commonly expressed in Nephelometric Turbidity Units (NTU). However, the supplied models and specifications below describe conductivity and salinity sensors rather than turbidity sensors. The content has therefore been organized to accurately reflect the listed conductivity sensor information.

Models

  • Four-Electrode Conductivity Sensor: A compact digital probe designed for inline process monitoring, environmental water quality checks, and integration with the Y600-A Handheld Meter.
  • Online Conductivity (Salinity) Sensor: A submersible industrial probe designed to measure electrical conductivity across a broad range, supporting salinity monitoring in demanding water applications.
  • Deep-Water Multi-Parameter Module: A specialized module designed for integration into deep-water monitoring equipment, such as the Y4003 Deep Water Sonde, for water quality measurements in deep wells and high-pressure environments.

Technical Specifications

  • Measurement Technology: Four-electrode conductivity measurement.
  • Conductivity Range: 0–200 mS/cm, with automatic range segmentation into 0–2 mS/cm, 2–20 mS/cm, and 20–200 mS/cm.
  • Salinity Range: 0–175 ppt.
  • Total Dissolved Solids (TDS): Stated upper measurement limit of 128,000 mg/L.
  • Communication Interface: RS-485 supporting the MODBUS-RTU protocol.
  • Enclosure Protection: IP68-rated housing for suitable submersible applications.

Working Principle

The conductivity sensor uses four-electrode electrochemical measurement technology to determine the electrical conductivity of water. Compared with conventional two-electrode designs, a four-electrode arrangement helps reduce errors associated with electrode polarization and contact resistance, particularly across a wide conductivity range.

The outer pair of electrodes applies an alternating electrical signal to the water, producing a current through the sample. The inner pair measures the resulting voltage drop. The sensor uses these electrical measurements to calculate conductivity.

Dissolved salts and minerals dissociate into positively and negatively charged ions, allowing water to conduct electricity. In general, higher concentrations of dissolved ions result in higher conductivity, although the relationship depends on the composition and temperature of the sample.

The sensor’s electronics can use conductivity and temperature measurements to calculate or estimate salinity and total dissolved solids (TDS). These derived values depend on the instrument’s conversion algorithms and the characteristics of the water being measured.

Applications

  • Aquaculture Operations: Monitoring salinity in freshwater, brackish-water, and marine aquaculture systems to help maintain suitable conditions for fish and shrimp.
  • Industrial Water and Wastewater: Monitoring conductivity in process water, treatment systems, and industrial wastewater streams.
  • Oceanography and Estuary Monitoring: Tracking changes in salinity associated with tidal movement, freshwater mixing, and saltwater intrusion in coastal areas.
  • Hydroponic Agriculture: Monitoring electrical conductivity (EC) to help manage nutrient solution concentrations in hydroponic systems.
  • Deep-Water Monitoring: Measuring water quality parameters in deep wells and other submersible monitoring applications when supported by the selected probe configuration.