Pressure

Bourdon Tube
7 products
Boiler
2 products
Chemical
3 products
Phenolic
1 product
Differential
7 products
Capsule
3 products
Test Pressure Gauge
5 products
Contact
4 products
Diaphragm
3 products
Diaphragm Seal
1 product
Digital
2 products
Pressure Transmitter
10 products
Pressure Switch
5 products
Load and Force
11 products
Accessories
15 products
Temperature

RTD
5 products
Bimetallic
2 products
Gas Filled
2 products
Non-Replaceable Inserts
3 products
Replaceable Inserts
4 products
Ceramic Protection
7 products
Mineral Insulated
4 products
Flameproof and Intrinsically Safe
7 products
Surface and Machinery
30 products
Food and Pharma
7 products
HVAC
9 products
Acids, Alkalis, Salts
4 products
Temperature Switch
1 product
Thermowell
16 products
Indicator, Controller
8 products
Accessories
9 products
Humidity
7 products
Thermocouple
50 products
Cable Sensors
38 products
Head Sensors
9 products
High Temperature
6 products
Temperature Transmitter
6 products
Flow

Electro Magnetic
2 products
Vortex
3 products
Swirl
1 product
Ultrasonic
7 products
Coriolis Mass Flowmeter
28 products
Positive Displacement
6 products
Variable Area
1 product
Differential Pressure
7 products
Turbine
4 products
Flap
1 product
Side Glass
1 product
Thermal gas
5 products
Air Flow/Quality
11 products
Flow Switch
9 products
Flow Computer
3 products
Flow Accessories
2 products
Dosing/Batching
6 products
Level

Radar
3 products
Ultrasonic
1 product
Capacitance
7 products
Conductivity
4 products
Magnetic
1 product
Float/Buoyancy
7 products
Level Indicator
3 products
Vibrating Rod
3 products
Rotary Paddle
2 products
Hydrostatic
2 products
Optical
1 product
Level Switches
11 products
Calibration Devices

Multi Function Calibrators
2 products
Pressure Calibrators
4 products
Temperature Calibrators
6 products
Valve Testing
1 product
Calibration Software
1 product
Valves

Actuator
1 product
Ball Valves
2 products
Butterfly Valves
3 products
Gate Valves
2 products
Globe Valves
3 products
Analytical Sensors

Water Quality Sensors
16 products
Process Systems
11 products
Density and Concentration
12 products
Analytical Controller
2 products
Process Systems
CMM 500 Compressor Master Meter
The CS Instruments CMM 500 Compressor Master Meter is a high-precision reference flow meter engineered to measure the performance and Free Air Delivery (FAD) of compressors. Operating on the Venturi differential pressure principle according to ISO 5167, it delivers highly accurate readings (±0.5% accuracy) even in wet, saturated compressed air directly downstream of the compressor without requiring long straight pipe runs. The CMM 500 can be used both directly downstream of the compressor for measuring wet compressed air and as a compressed air meter for consumption measurement and billing of dry compressed air.
SKU:
CMM500
Categories: Air Flow/Quality, Differential Pressure, Flowmeter
Description
Description
CS Instruments CMM 500 Compressor Master Meter – High-Precision Flow Measurement
The CS Instruments CMM 500 Compressor Master Meter is a high-precision reference flow meter designed to measure compressor capacity and compressed air consumption. It is suitable for measuring wet compressed air directly downstream of a compressor and dry compressed air in distribution systems.
Using a differential-pressure Venturi measurement principle, the CMM 500 delivers fast, accurate flow measurement across a wide operating range. Moreover, its low pressure loss and broad measuring span make it suitable for compressor performance testing, energy audits, and compressed air consumption monitoring.
With accuracy better than ±0.5% of measured value over the specified operating range, the CMM 500 supports reliable compressor capacity evaluation and applications requiring precise compressed air measurement.
Key Specifications
- Manufacturer: CS Instruments
- Model: CMM 500
- Instrument type: Compressor master meter / reference flow meter
- Measurement principle: Differential pressure using a Venturi measuring section
- Measuring medium: Air and compatible gases
- Measuring span: Greater than 1:130
- Accuracy: ±0.5% of measured value from 20% to 100% of maximum flow; lower-range accuracy depends on configuration
- Response time: Less than 1 second (t99)
- Medium temperature: −20°C to +100°C
- Operating pressure: Up to 16 bar(g); 30 bar(g) and 100 bar(g) versions available on request
- Pressure loss: Less than 70 mbar at maximum flow
- Power supply: 18–36 VDC
- Standard outputs: 4–20 mA, pulse, and RS-485 Modbus-RTU
- Optional interfaces: Modbus-TCP Ethernet, Power over Ethernet (PoE), and M-Bus
- Process connection: DIN EN 1092-1 or ANSI flanges
- Nominal sizes: DN 50, DN 80, DN 100, with DN 125, DN 150, and DN 200 available on request
Exact performance depends on the selected size, measuring section, gas properties, and installation conditions.
Working Principle
The CMM 500 uses the Venturi differential-pressure principle to determine gas flow.
- Gas enters the measuring section: Compressed air passes through the specially designed Venturi measuring section.
- Pressure difference develops: The geometry creates a pressure difference related to the gas velocity.
- Differential pressure is measured: The instrument measures the pressure difference across the measuring section.
- Flow is calculated: The electronics calculate flow using the differential pressure, calibrated measuring geometry, and configured gas properties.
- Operating conditions are considered: Pressure and temperature measurements support the calculation and display of standardised gas volume.
- Data is transmitted: Flow rate, total consumption, and other supported measurements are provided through the selected outputs or communication interfaces.
The CMM 500 can display standardised volume values such as Nm³ and Nm³/h. The reference conditions depend on the configured standard, such as DIN 1343 or ISO 1217 for compressed air.
Main Advantages
- High measurement accuracy: Supports precise compressor capacity measurement and compressed air consumption monitoring.
- Wide measuring range: A span greater than 1:130 accommodates substantial changes in demand.
- Fast response: A response time below one second helps capture short-term flow changes.
- Low pressure loss: Pressure loss remains below 70 mbar at maximum flow according to the manufacturer.
- Wet compressed air capability: Suitable for measurement directly downstream of a compressor under specified operating conditions.
- Dry compressed air monitoring: Can also be used for consumption measurement and billing applications.
- Flexible gas measurement: Supports compatible gases when the correct gas properties are configured.
- Multiple interfaces: Analogue, pulse, and digital communication options support integration into industrial monitoring systems.
- Serviceable design: The mounting plate allows maintenance activities such as zero-point correction, condensate drainage, and sensor replacement under the manufacturer’s specified procedures.
Typical Applications
The CMM 500 is suitable for:
- Compressor capacity and performance testing
- Free-air-delivery (FAD) assessment
- Compressed air energy audits
- Compressed air consumption monitoring
- Compressed air billing and submetering
- Industrial gas flow measurement
- Compressor comparison and efficiency evaluation
- Flow reference measurements in compressed air systems
Installation Considerations
Install the CMM 500 in a suitable horizontal pipe run or riser, following the manufacturer’s installation instructions. The selected measuring section and flange configuration must match the pipeline.
For high accuracy, use the recommended inlet and outlet measuring sections to establish stable flow conditions. Severe disturbances caused by valves, check valves, partially closed ball valves, or abrupt changes in pipe geometry may require additional flow conditioning.
Before selecting the meter, confirm the nominal pipe size, operating pressure, gas composition, temperature, required flow range, and desired output interfaces.
CMM 500 for Compressor Capacity Measurement
The CMM 500 is designed to provide a reliable reference for evaluating compressor output. By measuring flow directly at the compressor discharge, users can assess delivered compressed air volume and compare performance against expected capacity.
When combined with pressure, temperature, and electrical power measurements, the flow data can also support a broader compressor efficiency assessment. This helps identify underperforming compressors, compare operating conditions, and find opportunities to reduce energy costs.
Conclusion
The CS Instruments CMM 500 Compressor Master Meter is a high-precision flow measurement solution for compressor capacity testing and compressed air consumption monitoring. Its Venturi differential-pressure principle, wide measuring span, fast response, and low pressure loss make it suitable for demanding industrial applications.
For facilities that need dependable compressor performance data or accurate compressed air consumption measurements, the CMM 500 provides a versatile reference flow meter.
About CS Instruments
CS Instruments, from Germany, makes measuring instruments for compressed air and gases, and Schmierer SEA offers nine of them from Shah Alam: flow meters for consumption and compressor capacity, the LD500 and LD510 ultrasonic leak detectors with camera, and dew point, particle and oil vapour sensors for air quality. Our team helps you select the instrument and set it up.
Which CS Instruments product for which job
| Job | Product | Stated figures |
|---|---|---|
| Consumption in dry air | VA 500, 520, 550, 570 | Thermal mass flow, no moving parts; up to 40 bar (selected VA 520) or 50 bar (selected VA 550) |
| Wet air at the compressor outlet | VD 500 | -30 to +180 °C, up to 30 bar, DN 20 to DN 600 |
| Compressor capacity and billing | CMM 500 | ±0.5% of reading from 20 to 100% of maximum flow |
| Flow without cutting the pipe | VC600 | Clamp-on ultrasonic, pipes 25 to 90 mm outside diameter |
| Finding leaks | LD500 and LD510 | Leak rate and annual cost estimate per leak; LD510 adds a sensor input |
| Dew point and humidity | FA 510, FL 510 | Pressure dew point after the dryer; 0 to 100% RH |
| Particles | PC400 | From 0.1 µm or 0.3 µm, three size channels |
| Oil vapour | Oil Check500 | 0.001 to 5 mg/m³ at 3 to 9 bar |
| Air quality as one system | Compressed Air Quality Monitoring | Particle, moisture and oil sensors on one interface |
Where to start
- High energy bill: measure consumption with a VA sensor, then find the leaks with the LD500.
- Compressor performance in doubt: the CMM 500 is built as a reference meter for free air delivery.
- Air quality requirements: ISO 8573-1 classes air by particles, water and oil; the PC400, FA 510 and Oil Check500 measure each.
All CS Instruments products and the compact gas flow sensors we offer are on the compressed air flow meter page. Tell us the pipe size, pressure and what you need to know, and send an enquiry.
Related products
Massflow Sensor RHM12 middle size 0.75 – 100 kg/min
In stock
SKU:
RHM12
The RHM12 is a workhorse 1″ sensor used in every imaginable industry. Suitable for both continuous process and batching/filling applications, the RHM12 is a truly versatile tool for plant operations everywhere.
PDF datasheet
Massflow Sensor RHM160 large size 600 – 30000 kg/min
In stock
SKU:
RHM160
The RHM160 is the ultimate cargo and pipeline meter. With a combination of high accuracy and low pressure drop, the RHM160 is the perfect solution for rapidly transferring large fluid quanties with confidence.
PDF datasheet
Massflow Transm. RHE 15 – PROFIBUS DP Module
In stock
SKU:
RHE 15
The RHE15 is an expansion module providing connectivity for an RHE14 transmitter to a PROFIBUS-DP system. The unit can optionally act as a gateway for other local instruments without PROFIBUS functionality.
PDF datasheet
SSEA-UCOF Ultrasonic Clamp-On fixed Flow Meter
In stock
SKU:
SSEA UCOF
The Schmierer SEA SSEA-UCOF Ultrasonic Clamp-On Flow Meter measures liquid flow without requiring direct contact between the sensor and the process liquid. Its clamp-on ultrasonic transducers mount on the outside of the pipe. Therefore, installation does not require cutting the pipeline or stopping the flow.
The SSEA-UCOF uses digital signal processing technology to measure liquid flow across a wide range of pipe sizes. In addition, its wall-mounted transmitter, backlit LCD, and multiple output options support industrial monitoring and control. The meter also offers data logging capability through the manufacturer's FlowData software, making it useful for flow monitoring, system verification, and process optimization.