Exia Intrinsically Safe Cable Temperature Sensors

Measure temperatures safely in tight, explosive gas and combustible dust zones with ATEX-certified intrinsically safe cable probes. Therefore, petrochemical engineers, OEM machinery builders, and pharmaceutical plant operators deploy Limatherm Exia cable temperature sensors. Specifically, they rely on these compact, direct-lead RTDs and thermocouples where bulky explosion-proof connection heads cannot fit. Because these probes strictly limit electrical and thermal energy, they prevent ignition sparks completely. Furthermore, their chemical-resistant cables route easily through hazardous conduits. Consequently, your facility achieves full ATEX Zone 0, Zone 1, and Zone 20 compliance. As a result, you maintain fast, reliable thermal control across volatile industrial environments.

SKU: PTOP-Exi, PTTK-Exi, PTTJ-Exi Categories: , , ,
Description

Description

Product Types

The Limatherm intrinsically safe Exia cable sensor platform maps into three core sensing technologies. Thus, you can match your exact process temperature limits and accuracy requirements:

  • PTOP-Exi Series (Intrinsically Safe Cable RTDs): Outfitted with high-purity Pt100, Pt500, or Pt1000 platinum elements per EN 60751. Therefore, it delivers superior measurement accuracy from -200°C up to +400°C (cable dependent).
  • PTTK-Exi Series (Intrinsically Safe Type K Cable Thermocouples): Built with NiCr-Ni junctions per EN 60584. Consequently, it provides fast high-temperature tracking up to +1150°C (with mineral-insulated sheaths).
  • PTTJ-Exi Series (Intrinsically Safe Type J Cable Thermocouples): Engineered with Fe-CuNi junctions per EN 60584. Thus, it handles medium-heat hazardous machinery and pipelines safely up to +750°C.

Working Principle

The sensor operates continuously within an intrinsically safe (Ex ia) circuit connected to an approved Zener barrier or galvanic isolator in the safe area. First, process heat transfers directly onto the slim stainless steel or Inconel 600 protective sheath. Next, the internal platinum resistor or thermocouple junction captures this temperature shift immediately. Thus, it generates a low-energy resistance change or thermoelectric millivolt signal. Because the intrinsic safety barrier restricts voltage, current, and stored energy below ignition thresholds—even under fault conditions—no spark or excessive surface heating can occur. Finally, the factory-sealed extension cable transmits this clean signal safely back to your control system.

Key Specs

Technical Parameter Manufacturer Specification
Explosion Protection ATEX / IECEx Certified Intrinsically Safe (II 1/2G Ex ia IIC T1–T6 / II 1/2D Ex ia IIIC)
Sensing Elements PTOP-Exi: Single/Double Pt100, Pt500, Pt1000 / PTTK-Exi: Type K / PTTJ-Exi: Type J
Operating Temperature Range RTD models: -200°C to +400°C / Thermocouples: -40°C up to +1150°C (sheath & cable dependent)
Sheath Metallurgy & Size AISI 316L (1.4404) or Inconel 600 sheaths; slim outer diameters from 1.5 mm, 3 mm, 4.5 mm, up to 6 mm
Cable Insulation Options Blue Ex-marked PVC (+105°C), Silicone (+180°C), PTFE/Teflon (+260°C), or Fiberglass (+400°C)
Ingress Protection Class IP65 to IP67 hermetically sealed sheath-to-cable transition (insulation dependent)

Product Models & Functional Configurations

The Limatherm intrinsically safe Exia cable sensor catalog offers tailored mechanical builds. Moreover, it includes verified factory lead and mounting options:

  • Mineral-Insulated Bendable vs. Rigid Sheaths: Configured with compacted MgO mineral-insulated probes that bend easily around obstacles, or rigid stainless steel tubes for direct insertion pockets.
  • Tailored Ex-Grade Cable Jackets & Shielding: Supplied with chemically resistant PTFE, flexible silicone, or shielded blue PVC leads clearly marked for intrinsically safe circuits.
  • Smooth, Threaded, or Bayonet Process Mounts: Available with plain sheaths for compression fittings, fixed male threads (G1/4″, G1/2″, M10x1), or spring-loaded bayonet caps.
  • 2-Wire, 3-Wire, or 4-Wire RTD Circuits (PTOP-Exi): Engineered in 2-wire, 3-wire, or 4-wire configurations. Consequently, technicians eliminate lead-wire resistance errors over long runs to the safe-area barrier.

Advantages

  • Certified Zone 0, Zone 1 & Zone 20 Safety: Strict Ex ia energy limitation prevents electrical sparks and hot surfaces. As a result, your plant monitors temperatures safely inside explosive gas, vapor, and combustible dust zones.
  • Ultra-Compact Headless Footprint: Eliminating bulky flameproof connection heads allows installation inside tight machinery cavities, bearings, and narrow manifolds. Therefore, engineers save space and simplify routing.
  • Fast Thermal Response Times: Slim stainless steel and mineral-insulated sheaths transfer heat almost instantaneously to the internal sensing tip. Consequently, your control loop reacts rapidly to sudden exothermic temperature spikes.
  • Superior Vibration & Chemical Resistance: Hermetically sealed transitions, PTFE cable jackets, and compacted MgO insulation withstand heavy pump vibrations and corrosive vapors reliably.

Applications

Process safety, OEM, and instrumentation engineers integrate Limatherm Exia cable temperature sensors across hazardous environments:

  • Chemical & Pharmaceutical Skids: Fits inside compact pilot reactors, solvent recovery units, and centrifuge bearings in Zone 1 and Zone 2 areas.
  • Oil, Gas & Compressor Packages: Monitors bearing housings, lubrication lines, and manifold temperatures under continuous mechanical vibration.
  • Grain Silos, Flour Mills & Dust Collectors: Tracks equipment and duct temperatures safely inside combustible dust Zone 20 and Zone 21 environments.
  • Paint Booths & Solvent Drying Ovens: Delivers fast, spark-safe thermal feedback inside volatile vapor extraction ducts and curing chambers.
About Limatherm

Products & Features

Limatherm specializes in industrial temperature measurement and control solutions. Core Products & Services are 

  • Temperature Sensors: wired and head sensors, mineral-insulated (sheathed) RTD and Thermocouples
  • Hazardous Area Solutions: intrinsically safe (Exia) and flameproof (Exd) 
  • Accredited Laboratory: acc. to ISO/IEC 17025 standard
  • High-Temperature Patent:  up to 2300°C
  • Material Diversity: acid-resistant steel, borosilicate glass, ceramics (e.g., Hexoloy)

Key Benefits

  • Reliability in Extreme Environments: Suitable for high-temperature and harsh conditions (e.g., molten metal, acidic environments).
  • Adaptability: Suitable for diverse industries such as metallurgy, chemical processing, and food production.
  • Easy Installation: Features like replaceable inserts and flexible mineral-insulated cables reduce maintenance time and cost.