deltaflow DF Pitot Tube with LSP Air Purge Unit

The systec Controls deltaflow DF Pitot Tube measures the flow of gases, steam and liquids using the differential-pressure principle. Its specially designed averaging Pitot profile measures the pressure difference created by flowing media. Moreover, it offers low permanent pressure loss and reliable performance in demanding industrial environments.

For dusty gases or media with high particulate content, the optional LSP Air Purge Unit helps keep the probe’s pressure channels clear. It automatically uses compressed air to clean the measuring passages at configurable intervals. Consequently, the combined system supports reliable flow measurement while reducing the need for manual cleaning.

SKU: Deltaflow DF Categories: ,
Description

Description

Models and Configurations – systec Controls deltaflow DF Pitot Tube with LSP Air Purge Unit

The deltaflow range includes different probe designs for different pipeline sizes and process conditions.

  • DF12: A compact probe used for smaller pipelines, including applications around DN20–DN80.
  • DF25: A widely used averaging Pitot tube for larger pipelines. It is designed for robust flow measurement in demanding gas, steam and liquid applications.
  • DF44: A probe designed for very large ducts and pipelines, with application-specific pressure, temperature and material configurations.

LSP Air Purge Unit

The LSP air purge system is an accessory for applications where dust, dirt or condensation may obstruct the probe’s pressure channels.

It is installed between the deltaflow probe and the differential-pressure transmitter. At configured intervals, it uses compressed air to flush the measuring passages. The system can be configured for the required measurement arrangement and purging sequence.

Key Specifications

  • Manufacturer: systec Controls
  • Measurement Principle: Differential pressure using an averaging Pitot tube
  • Measured Media: Gases, steam and compatible liquids
  • Measurement Direction: Bidirectional measurement is possible with suitable configurations
  • Pressure Loss: Low permanent pressure loss compared with many conventional differential-pressure primary elements
  • Measurement Range: Up to 1:30 or greater, depending on application and configuration
  • Typical Accuracy: From approximately 0.4% for suitable configurations; actual system accuracy depends on installation and operating conditions
  • Standard Probe Material: Stainless steel 1.4571 (316Ti), with alternative materials available for selected versions
  • LSP Function: Automatic air purging of the pressure channels
  • LSP Utilities: Compressed air and auxiliary electrical power, as required by the selected system
  • Transmitter Compatibility: Suitable differential-pressure transmitters or compatible multivariable transmitters, such as the SYS-MMF
  • Installation: Insertion probe installed through a suitable pipeline connection

Important: Pressure rating, temperature limits, accuracy and material options differ between DF models. Select the probe and LSP configuration according to the process conditions and the manufacturer’s latest documentation.

Working Principle

1. Flow Measurement with the deltaflow DF Pitot Tube

As fluid passes the probe, the specially shaped profile creates pressure differences between its upstream and downstream measuring openings. The probe collects these pressure signals and produces a differential-pressure value related to the flow velocity.

A compatible differential-pressure transmitter measures this value. The flow rate can then be calculated using the appropriate flow equation and configured pipeline and fluid properties.

Because the deltaflow uses an averaging profile, it samples pressure across the flow rather than relying on a single-point measurement. This helps provide representative measurements when the installation and flow conditions are suitable.

2. Automatic Cleaning with the LSP Air Purge Unit

In dusty or contaminated applications, particles and condensation can gradually obstruct the pressure channels. This may cause unstable readings, measurement errors or loss of the differential-pressure signal.

The LSP helps address this problem by periodically flushing the probe’s pressure passages with compressed air. Its control system operates the purge sequence at configured intervals. As a result, the measuring channels remain clearer and the system can maintain more reliable readings between maintenance activities.

Advantages

  • Low Permanent Pressure Loss: Helps reduce energy losses in industrial pipelines.
  • Robust Measurement: Suitable for demanding gas, steam and liquid applications.
  • Contamination Resistance: The probe design helps reduce the effects of dust and deposits.
  • Automatic Air Purging: The LSP helps prevent pressure-channel blockage in heavily contaminated applications.
  • Reduced Manual Cleaning: Scheduled purging can reduce maintenance interventions.
  • Flexible Integration: Compatible with suitable differential-pressure and multivariable transmitters.
  • Wide Application Range: Multiple probe designs and materials support different pipeline and process requirements.
  • Improved Measurement Continuity: Keeping pressure channels clear helps reduce errors caused by blockage.

Applications

The deltaflow DF Pitot Tube with LSP Air Purge Unit is suitable for:

  • Power generation and boiler systems
  • Flue gas and exhaust gas flow measurement
  • Dust-laden industrial gases
  • Cement and mineral processing
  • Waste incineration plants
  • Chemical and petrochemical facilities
  • Combustion air measurement
  • Steam flow measurement
  • Large industrial ducts and pipelines

Installation and Selection

First, identify the process medium and determine whether the application involves dust, sticky particles or condensation. Next, select the appropriate DF probe according to the pipe diameter, operating pressure, temperature and required measurement range.

For contaminated service, assess whether an LSP air purge unit is needed. Confirm that the available compressed air is suitable and that the purge sequence is compatible with the process and transmitter arrangement.

Finally, select a compatible differential-pressure transmitter or multivariable transmitter. Correct probe orientation, installation location, pressure connections and configuration are essential for reliable flow measurement.

Conclusion

The systec Controls deltaflow DF Pitot Tube provides robust differential-pressure flow measurement with low permanent pressure loss. When combined with the LSP Air Purge Unit, it is particularly useful for dusty or contaminated applications where blocked pressure channels could affect measurement reliability.

Together, the probe and purge system offer a practical solution for industrial plants that need dependable flow monitoring and reduced manual cleaning.

About Systec Controls

Products & Features

Systec Controls from Germany specializes in Differential Pressure (DP) and Ultrasonic Transit Time flow technologies for gas and steam. Their systems are designed for extreme industrial conditions, high temperatures, high pressures, and contaminated media.

Differential Pressure Technology (Deltaflow Series):
This technology uses the proven differential pressure principle, where a primary element (like a Pitot Tube or Venturi) creates a pressure drop proportional to the flow velocity.

Ultrasonic Transit Time Technology (Deltawave Series):
This technology measures the time difference between ultrasonic signals traveling with and against the flow direction. It is virtually maintenance-free as it has no moving parts or pressure loss.

Key Benefits

  • Cost Savings: Clamp-on technology saves significantly on installation time and operating costs, as there is no need to interrupt the process.
  • Low Energy Consumption: The deltaflow system is designed to have very low pressure losses, resulting in energy savings.
  • Long-Term Reliability and Robustness: designed for longevity, robust sensors against fouling (soiling).100% Maintenance free clamp on ultrasonic systems
  • Optimized DP Technology: lowest pressure loss with high precision
  • Easy Installation and a uniform display concept for both portable and permanently mounted devices.