Outdoor Weather HVAC Temperature Sensors

Measure exterior ambient temperatures accurately in shaded and sun-exposed locations for weather-compensated HVAC and district heating control. Therefore, building automation integrators, district heating operators, and HVAC contractors deploy Limatherm TOPZ-850 and TONZ-850 outdoor sensors. Specifically, they rely on these rugged, polycarbonate-housed probes to track outdoor climate changes continuously. Because these models combine precision platinum or nickel resistance elements with weatherproof IP65 enclosures and optional solar shields, they resist rain, snow, and UV radiation completely. Furthermore, they provide rapid thermal response. Consequently, your heating and cooling systems adjust supply temperatures proactively. As a result, you optimize energy efficiency across commercial and residential buildings.

SKU: TOPZ-850, TONZ-850 Categories: ,
Description

Description

Product Types

The Limatherm TOPZ-850 and TONZ-850 outdoor sensor platform maps into two core sensing element families and specialized radiation-shield configurations. Thus, you can match your exact BMS controller input and wall exposure:

  • TOPZ-850 (Platinum RTD Outdoor Sensors): Outfitted with high-purity Pt100 or Pt1000 elements per EN 60751. Therefore, they deliver high measurement accuracy and long-term stability across modern building automation networks.
  • TONZ-850 (Nickel RTD Outdoor Sensors): Engineered with Ni100 or Ni1000 elements per DIN 43760. Consequently, they integrate seamlessly into legacy and European HVAC controllers requiring higher temperature coefficients.
  • Standard vs. Solar-Shielded Enclosures: Available in standard IP65 polycarbonate housings for north-facing shaded walls, or outfitted with protective sun shields for direct sun-exposed installations.

Working Principle

The sensor operates continuously by measuring exterior air temperature through a weather-sealed polycarbonate enclosure or external probe tip. First, ambient outdoor air passes across the sensor housing while the UV-resistant shell blocks rain, wind-driven snow, and direct solar radiation. Next, the internal platinum (TOPZ-850) or nickel (TONZ-850) sensing element captures outdoor temperature shifts immediately. Thus, it generates a predictable, linear shift in electrical resistance corresponding to the active weather condition. Finally, the internal screw terminal block or optional active transmitter routes this clean signal directly to your weather-compensated heating controller, BMS, or PLC.

Key Specs

Technical Parameter Manufacturer Specification
Sensing Elements TOPZ-850: Pt100 or Pt1000 (EN 60751) / TONZ-850: Ni100 or Ni1000 (DIN 43760)
Operating Temperature Range Exterior Weather Spectrum: -50°C up to +80°C continuous outdoor operation
Enclosure Material Impact-resistant, UV-stabilized Polycarbonate weatherproof housing
Ingress Protection Class IP65 dust-tight and water-jet protected per EN 60529
Signal Output Options Direct passive 2-wire, 3-wire, or 4-wire RTD resistance, or active 4–20 mA / 0–10 V output
Cable Entry & Mounting Bottom-entry PG / M16 waterproof cable gland with integrated exterior wall-mount tabs

Product Models & Functional Configurations

The Limatherm TOPZ-850 and TONZ-850 outdoor weather sensor catalog offers tailored building automation configurations. Moreover, it includes verified factory output and protection options:

  • Pt100 / Pt1000 vs. Ni100 / Ni1000 Elements: Configured with Pt1000 or Ni1000 sensors to eliminate lead-wire resistance errors over long 2-wire exterior cable runs, or Pt100 elements for high-precision 3-wire and 4-wire PLC loops.
  • Sun & Radiation Shield Add-On: Outfitted with a ventilated protective sun guard. Consequently, sensors mounted on south-facing or unshaded walls measure true ambient air temperature without solar heat-soak errors.
  • Passive Resistance vs. Active Transmitter Outputs: Supplied as direct passive RTD sensors for standard weather controllers, or outfitted with integrated 4–20 mA or 0–10 V signal conditioners.
  • Bottom-Entry Waterproof Cable Gland: Features a downward-facing PG/M16 cable gland and captive lid screws. As a result, rainwater drains away from the seal, preventing moisture ingress over years of outdoor exposure.

Advantages

  • Accurate Sun-Exposed & Shaded Readings: Optional solar radiation shields prevent direct sunlight from skewing measurements. As a result, weather-compensated heating curves remain accurate throughout sunny winter days and summer peaks.
  • Rugged IP65 Polycarbonate Weatherproofing: UV-stabilized, impact-resistant polycarbonate enclosures endure freezing blizzards, driving rain, and harsh sunlight without cracking or yellowing.
  • Universal BMS & Heating Controller Compatibility: Offering both platinum (TOPZ-850) and nickel (TONZ-850) elements ensures plug-and-play compatibility with Siemens, Danfoss, Honeywell, and standard PLC inputs.
  • Fast, Maintenance-Free Wall Installation: External mounting lugs and spacious screw terminals let technicians install and wire the unit cleanly in minutes without opening internal circuit boards.

Applications

HVAC engineers, district heating utilities, and building integrators deploy Limatherm TOPZ-850 and TONZ-850 outdoor sensors across exterior climate control systems:

  • Weather-Compensated Boiler & Heat Pump Control: Adjusts heating water flow temperatures automatically based on real-time outdoor temperature drops to maximize fuel savings.
  • District Heating & Substation Networks: Monitors exterior ambient conditions at municipal heat-exchanger substations for predictive load balancing.
  • Commercial Building HVAC & Chiller Plants: Controls economizer dampers, free-cooling cycles, and frost-protection interlocks reliably.
  • Greenhouses, Cold Storage & Industrial Facilities: Delivers continuous, weather-resistant ambient temperature feedback for automated ventilation and climate management.
About Limatherm

Products & Features

Limatherm specializes in industrial temperature measurement and control solutions. Core Products & Services are 

  • Temperature Sensors: wired and head sensors, mineral-insulated (sheathed) RTD and Thermocouples
  • Hazardous Area Solutions: intrinsically safe (Exia) and flameproof (Exd) 
  • Accredited Laboratory: acc. to ISO/IEC 17025 standard
  • High-Temperature Patent:  up to 2300°C
  • Material Diversity: acid-resistant steel, borosilicate glass, ceramics (e.g., Hexoloy)

Key Benefits

  • Reliability in Extreme Environments: Suitable for high-temperature and harsh conditions (e.g., molten metal, acidic environments).
  • Adaptability: Suitable for diverse industries such as metallurgy, chemical processing, and food production.
  • Easy Installation: Features like replaceable inserts and flexible mineral-insulated cables reduce maintenance time and cost.