Pressure
Temperature
Bimetallic
1 product
TC
0 products
Gas filled
4 products
Thermowell
8 products
Ceramic Protection Tube
2 products
Replaceable measuring inserts
7 products
Non-Replaceable Measuring Inserts
3 products
Surface and Machinery Sensors
35 products
For Food and Pharmaceutical Industry
7 products
For HVAC Applications
9 products
For Acids, Alkalis, and Salts
4 products
Flameproof and Intrinsically Safe
5 products
Transmitters and Accessories
14 products
Accessories
5 products
Flowmeter
Electro Magnetic
0 products
Vortex
4 products
Swirl
0 products
Ultrasonic
2 products
Positive Displacement
6 products
Variable Area
9 products
Differential Pressure
9 products
Gas Turbine
0 products
Flap
3 products
Side Glass
0 products
Thermal gas
1 product
Level
Radar
5 products
Ultrasonic
0 products
Capacitance
13 products
Conductivity
0 products
Magnetic
1 product
Float
0 products
Buoyancy
0 products
Tube
4 products
Vibrating Rod
3 products
Rotary Paddle
2 products
Level Switches
27 products
Analytical
Process Systems
30 products
Concentration
10 products
Density
10 products
Chlorine
0 products
Conductivity
5 products
PH
0 products
Redox
0 products
Calibration Devices
Multi Function Calibrators
2 products
Pressure Calibrators
3 products
Temperature Calibrators
4 products
Valve Testing
1 product
All products
Integral Orifice Assembly Flow Sensor
The integral orifice assembly is a pipe segment for small flow measurement of liquids and gases.
– small pipe diameters (bore)
– high accuracy/precision
– with differential pressure transmitter
– easy installation / simple maintenance
– various materials
6
People watching this product now!
SKU:
Integral Orifice Assembly
Categories: Differential Pressure Flowmeter, Flow, Orifice
Description
Description
The integral orifice assembly is designed to be mounted to the differential pressure transmitter directly. The integral orifice assembly is a pipe segment for measurement of small flows. It is suitable for liquids and gases. The integral orifice is the differential pressure sensor and is mounted inside the assembly. While the medium to be measured passes through the orifice, a pressure drop occurs. This value is proportional to the flow. A differential pressure transmitter transforms the pressure loss into a standardized signal, like a current output (4…20 mA). The integrated flowmeter eliminates the need for fittings, tubing, valves, adapters, and mounting brackets, thereby reducing welding and installation time.
| Media | liquids or gases |
| Measuring ranges liquids | 0.396 to 1109.52 GPH, 1.50 to 4200 l/h |
| Measuring ranges gases | 1.766 to 4238 ft³/h, 0,05 to 120 m³/h |
| Inside diameter of the integrated orifice | 0.5 – 9.5 mm |
| Nominal pressure (max) | ANSI 2500 # (PN 420) |
| Medium Temperature | -40…+248°F, -40…+120°C |
| Process Connection | ½“ NPT-F |
| Material wetted parts | 316Ti (1.4571) Hastelloy, Monel or other material on request |
Related products
Electro Magnetic Flow Meter SSEAMFI
In stock
SKU:
SSEAMFI
The Schmierer SEA Electro Magnetic Flowmeter Range is based on Faraday's Law of Electromagnetic Induction. When the conductive fluid flows through a magnetic field of the sensor, an electric voltage proportional to the volume flow is generated between the pair of electrodes and transmitted to the output device.
The flow and volume will be displayed at the electronic transmitter
No disturbance or restriction of flow
No moving parts - no wear and tear, virtually no pressure loss
Insensitive to fluid density, temperature, pressure, viscosity
Can be used for different types of conductive liquids (calibration with water required)
download pdf datasheet
Flap Flowmeter KFS spring loaded
In stock
SKU:
KFS Flap
The KFS spring loaded measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated to customer requirement and fitted with a product-specific scale. The 50 mm thick ring features a half-round plate that is fastened to a rotating spring-loaded spindle. The angle between flap and ring changes according to the rate of flow, and a breakaway-proof magnetic coupling transfers the movement to an external pointer.
download pdf datasheet
Flap Flowmeter KLA
In stock
SKU:
KLA Flap
The KLA Flowmeter uses a flap which is deflected by the flow of the medium. The deflection angle is a direct indication of the flow through the pipe. The flap is gravity-loaded, thus the device can be used for the flow directions left to right, right to left and bottom to top.
In the variant KLA-GS the medium be measured is directly visible through a glass in the flow indication unit.
download pdf datasheet
Massflow Sensor RHM03 small size 0.038 – 5 kg/min
In stock
SKU:
RHM03
The RHM03 is available with a wide selection of wetted materials and the highest pressure and temperature ratings in the market. It is suitable for all low flow applications where high accuracy is a must.
PDF datasheet
Massflow Sensor RHM12 middle size 0.75 – 100 kg/min
In stock
SKU:
RHM12
The RHM12 is a workhorse 1″ sensor used in every imaginable industry. Suitable for both continuous process and batching/filling applications, the RHM12 is a truly versatile tool for plant operations everywhere.
PDF datasheet
Thermal Gasflow Meter
In stock
SKU:
Thermal Flow TA
Fixed and portable consumption measurement in compressed air, nitrogen, natural gas, methane, helium, argon, carbon dioxide, hydrogen, SF6; measuring laminar flow, burner supply air, leakage flows; monitoring safety-related installations, also in aeronautical applications.
- for use in air, compressed air, nitrogen, natural gas, methane, deposit gas, argon, helium, propane, butane, CO2, SF6
- probe for pipeline installation from Di 25 mm, measuring tube from Di 8 mm
- measurement of gas mass flow
- standard flow velocity 0.08 m/s to 200 m/s, volume flow up to 0.04 m3/h
- time constant of under 1 s
- for applications in Ex areas
- M-Bus, WLAN
VA Flowmeter RA77/FA77 plastic tube – glass cone
In stock
SKU:
RA77/FA77
VA Flowmeter with plastic armature and borosilicate glass measuring cone
Measuring units RA 77 and FA 77 are based on the variable area float principle.
The flow meter consist of a PVC armature with a measuring cone made of borosilicate glass. With these design features the RA 77 / FA 77 devices combine the advantages of the classical VA flow meters with those of pure plastic measuring devices: Cost-effective, resistant against almost all aggressive media, as well as a high accuracy of the measuring glass, which can be calibrated to suit any requirement. Especially with water and aggressive media this design has proven itself. Therefore the RA 77 / FA 77 are frequently used in the chemical industry and in water treatment plants.
By installation of electrical limit value switches, which are adjustable throughout the entire measuring range, this devices can be used as detectors.
download pdf datasheet
VA Flowmeter SGA NBR lining
In stock
SKU:
SGA
VA Flow Meter with NBR-lining for acids, alkaline solutions and aggressive gases
The measuring unit SGA is based on the variable area float principle.
Wherever a robust and reliable device for the indication of momentary values and the monitoring of flows in pipelines is required in plant engineering, the SGA is the right choice as a reliable unit for the measurement of liquids and gases. This flow meter is available in a variety of cast iron versions for the application with various media and pressures.
The measuring range for H2O is 0.012 - 0.12 m3/h to 12 - 120 m3/h, the measuring range for gas is 0.15 - 1.5 to 100 - 1000 m3/h air at STP. Each unit is calibrated to meet the requirements of the respective customer and is fitted with a scale specific for the media to be measured.
download pdf datasheet