SYS-SMF Coriolis Mass Flow Meter – Explosion proof

The systec Controls SYS-SMF is a high-precision, inline Coriolis mass flow meter engineered for maximum accuracy and ultimate process reliability in demanding industrial liquid environments. Developed through continuous, multi-year research collaborations with renowned metrological institutions like the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, the University of Oxford, and TÜV, this premium device brings high-end metrological engineering down to an affordable price point. By determining multiple fluid characteristics instantly, it delivers an optimized process tracking solution that scales efficiently across complex B2B applications.

SKU: Coriolis SYS-SMF Categories: ,
Description

Description

systec Controls SYS-SMF Coriolis Mass Flow Meter – High-Precision Mass Flow, Density and Temperature Measurement

The systec Controls SYS-SMF Coriolis Mass Flow Meter provides high-precision measurement of mass flow, density, and volume flow in industrial processes. It uses the Coriolis measuring principle to determine mass flow directly, making it suitable for applications that require reliable measurement and accurate dosing.

Unlike conventional volumetric flow meters, the SYS-SMF measures mass flow independently of a fixed volumetric conversion. In addition, it determines liquid density and supports temperature measurement, providing several important process variables from one instrument. Its U-tube measuring design, robust construction, and flexible electrical interfaces also support integration into industrial process control systems.

Moreover, systec Controls developed the SYS-SMF in cooperation with research and testing organizations, including the University of Oxford, TÜV, and the Physikalisch-Technische Bundesanstalt (PTB). The manufacturer highlights its high measurement accuracy, broad measuring range, and suitability for demanding industrial applications.

Key Features

  • Direct mass flow measurement: Measures mass flow using the Coriolis principle rather than relying solely on volumetric flow calculations.
  • Multivariable measurement: Measures mass flow and density while also supporting temperature measurement and volume flow determination.
  • High measurement accuracy: Offers different accuracy classes depending on the selected model and calibration.
  • U-tube measuring design: Uses vibrating measuring tubes to detect changes associated with fluid flow and density.
  • Wide process temperature range: Different versions accommodate low, normal, and high-temperature applications.
  • Bidirectional measurement: Supports flow measurement in both directions when the selected configuration is suitable.
  • No straight inlet or outlet sections required: The Coriolis measuring principle does not require conventional upstream and downstream straight-pipe sections for flow profiling.
  • Flexible signal outputs: Standard outputs include 4–20 mA and active or passive pulse signals. Optional interfaces include HART and RS-485.
  • Industrial protection: The meter features an IP66 protection rating.
  • Convenient operation: Operators can configure the instrument using the front-panel controls or an optional infrared remote control, depending on the configuration
  • ATEX explosion protection certification, which shares technological parity with IECEx design requirements for zone-based global compliance: The Transmitter is housed in flameproof enclosure (Ex db),  the core sensor element utilizes intrinsic safety (Ex ib).
    • Gas Protection Marking: II 2G Ex db ib IIC T6…T1 Gb
    • Dust Protection Marking: II 2D Ex ib tb IIIC T80°C…T240°C Db

Working Principle

The SYS-SMF uses the Coriolis effect to measure mass flow. Inside the instrument, the measuring tubes vibrate at a controlled frequency. When fluid passes through these tubes, the moving mass interacts with the vibration and produces a Coriolis force.

Sensors detect the resulting changes in the tubes’ oscillation signals. When there is no flow, the signals from the two sensor positions remain in phase. However, when fluid flows through the tubes, the Coriolis force creates a phase shift between the signals. The transmitter evaluates this shift to determine the mass flow rate.

The instrument also determines fluid density by evaluating the resonant frequency of the vibrating measuring tubes. Because the resonant frequency changes with the mass contained within the tubes, it provides information about the fluid’s density.

As a result, the SYS-SMF can provide mass flow and density measurements without relying on a separate volumetric flow measurement. It can also support temperature measurement and volume flow determination, giving operators valuable information for process monitoring, dosing, and quality control.

Technical Specifications

  • Manufacturer: systec Controls
  • Model: SYS-SMF
  • Instrument type: Coriolis mass flow meter
  • Measuring principle: Coriolis effect using a U-tube measuring architecture
  • Measured variables: Mass flow, density, and volume flow; temperature measurement is also supported
  • Media: Primarily designed for liquids; gas measurement depends on the applicable model and configuration
  • Standard outputs: One 4–20 mA output, active pulse output, and passive pulse output
  • Optional outputs and communication: HART, RS-485, and two 4–20 mA outputs
  • Power supply: 18–265 V AC/DC
  • Power consumption: 15 W
  • Accuracy for liquids: Typically 0.1% of measured value, with other accuracy classes and optional 0.05% performance depending on the model and calibration
  • Accuracy for gases: Available performance depends on the model and configuration; confirm the applicable specification with the manufacturer
  • Low-temperature version (LT): -200°C to +50°C
  • Normal-temperature version (NT): -50°C to +150°C
  • High-temperature version (HT): 0°C to +350°C
  • Pressure ratings: PN16 to PN160; higher ratings may be available subject to configuration and confirmation
  • ANSI pressure classes: Class 150 to Class 900, depending on configuration
  • Protection rating: IP66
  • Standard measuring tube material: Stainless steel 316L (1.4404)
  • Optional measuring tube materials: Hastelloy C4, titanium, tantalum, and duplex stainless steel, subject to availability
  • Flange materials: Stainless steel 304, 316, or 316L; Hastelloy C4 and titanium may be available as options

Applications

  • Chemical processing: Measure and dose liquid chemicals and solvents in industrial production.
  • Food and beverage manufacturing: Monitor ingredients, fruit concentrates, juices, and other compatible liquids during processing and dosing.
  • Pharmaceutical production: Support precise liquid measurement in processes where accurate dosing is important.
  • Oil and fuel handling: Measure suitable fuels, crude oils, and other compatible hydrocarbon liquids.
  • Lubricant and grease processing: Monitor mass flow and density in compatible fluid handling systems.
  • Cleaning and solvent systems: Measure cleaning agents and solvents during transfer or batching.
  • Automated dosing systems: Provide mass flow data for controlled ingredient addition and batch production.
  • Process quality monitoring: Use density and flow information to monitor changes in fluid properties and process conditions.
  • Industrial transfer systems: Measure fluid flow where reliable mass measurement is more useful than volumetric measurement alone.

The SYS-SMF is particularly suitable for applications that require accurate measurement and dosing. However, users should confirm material compatibility and the required measurement performance for the specific process fluid.

Benefits of the systec Controls SYS-SMF

  • Accurate mass measurement: Direct mass flow measurement supports dosing, batching, and process control.
  • Multiple process variables: Mass flow, density, and temperature information help operators monitor process performance.
  • Reduced installation constraints: The measuring principle does not require conventional straight inlet and outlet sections for flow profiling.
  • Flexible integration: Analog outputs, pulse signals, and optional digital communication simplify integration with compatible PLCs and process control systems.
  • Broad process compatibility: Different temperature versions and optional corrosion-resistant materials support a variety of applications.
  • Bidirectional capability: Supports flow measurement in either direction when configured for the application.
  • Improved process monitoring: Density information provides an additional variable for monitoring fluid quality and process changes.
  • Calibration options: Different accuracy classes and calibration services allow users to select a suitable performance level for their requirements.

Conclusion

The systec Controls SYS-SMF Coriolis Mass Flow Meter combines mass flow measurement with density and temperature information in a single instrument. With its high-precision measuring principle, flexible interfaces, and different process temperature options, it provides a reliable solution for demanding industrial measurement, dosing, and process monitoring applications.

About Systec Controls

Products & Features

Systec Controls from Germany specializes in Differential Pressure (DP) and Ultrasonic Transit Time flow technologies for gas and steam. Their systems are designed for extreme industrial conditions, high temperatures, high pressures, and contaminated media.

Differential Pressure Technology (Deltaflow Series):
This technology uses the proven differential pressure principle, where a primary element (like a Pitot Tube or Venturi) creates a pressure drop proportional to the flow velocity.

Ultrasonic Transit Time Technology (Deltawave Series):
This technology measures the time difference between ultrasonic signals traveling with and against the flow direction. It is virtually maintenance-free as it has no moving parts or pressure loss.

Key Benefits

  • Cost Savings: Clamp-on technology saves significantly on installation time and operating costs, as there is no need to interrupt the process.
  • Low Energy Consumption: The deltaflow system is designed to have very low pressure losses, resulting in energy savings.
  • Long-Term Reliability and Robustness: designed for longevity, robust sensors against fouling (soiling).100% Maintenance free clamp on ultrasonic systems
  • Optimized DP Technology: lowest pressure loss with high precision
  • Easy Installation and a uniform display concept for both portable and permanently mounted devices.