Coriolis Mass Flow Meter SSEACMFVIII

The Schmierer SSEACMFVIII Coriolis Mass Flowmeter delivers high-accuracy multi-variable fluid measurement completely independent of fluid properties like viscosity or density. Direct mass flow, density, and temperature measurement for liquids, gases, and slurries. It tracks authentic mass dynamics without separate temperature or pressure compensation.

accuracy grades from(±0.15% to ±0.5
tube configuration models: U-tube, Straight, or Microbend

SKU: SSEACMFVIII Categories: ,
Description

Description

Product Overview

The platform features three distinct tube configuration options:

Coriolis Flow Meter Tube Configurations

  • US Series (U-Tube Type): This configuration maximizes the mechanical twisting force of the Coriolis effect. Specifically, it is engineered for custody transfer, bulk loading, and high-pressure dosing. Furthermore, it offers flexible line sizes ranging from 1/2″ (DN15) up to 10″ (DN250).
  • SS Series (Straight Tube Type): This design effectively minimizes pressure drop. Additionally, it ensures the meter remains easily cleanable. Consequently, it is ideal for abrasive slurries, sanitary environments, viscous liquid dosing, or frequent product swaps. Available line sizes span from 1/6″ (DN04) up to 4″ (DN100).
  • VS Series (Microbend Type): This acts as a reliable hybrid option. Notably, it offers a much smaller footprint than the US series while maintaining high sensitivity. Therefore, it serves as a compact model for piping retrofits and vibration-heavy zones. Its line sizes cover 1/4″ (DN08) up to 4″ (DN100).

Technical Specifications

The table below highlights the official specification choices available for the platform.

  • Measurement Accuracy: You can configure the system for ±0.15%, ±0.2%, or ±0.5% accuracy.
  • Medium Temperature: The standard range is -40°C to +85°C. However, a low-temp option extends from -200°C to +85°C.
  • Working Pressure: The housing is rated securely for ≤4 MPa, ≤6.3 MPa, or ≤10 MPa.
  • Wetted Material: Operators can choose between Stainless Steel 316L or Hastelloy C22.
  • Body Material: Specifically, the outer casing uses premium Stainless Steel 304.
  • Signal Output: The system provides 4~20 mA and Pulse output channels.
  • Communication Protocol: Next, you can select between None, HART, or RS485 Modbus.
  • Process Connection Type: It supports ANSI 150#, DIN PN40 flanges, or NPT Threaded links.
  • System Structure: Choose a Compact layout with a built-in display. Alternatively, select a Remote display with a bracket.
  • Power Supply: The device runs on 15–30 VAC or 15–40 VDC lines.

Working Principle

The device calculates real-time flow by using the fundamental physics of the Coriolis effect.

  • Tube Vibration: First, an electromagnetic drive actively vibrates the internal flow tubes.
  • Phase Shift Measurement: Next, fluid flowing through the vibrating structure induces a twisting motion due to Coriolis acceleration. Highly sensitive internal pick-up sensors capture this phase deflection symmetrically across the tube assembly. Finally, the microprocessor translates this precise time delay directly into a mass flow reading.
About SSEA

SSEA instruments are Schmierer SEA's own range, offered from Shah Alam and led by pressure gauges. The SRU 25 stainless steel pressure gauge uses a silicon-jelly stabiliser instead of liquid filling and is rated IP66. The STU02 bimetallic thermometer is built to EN 13190. Gauge accessories, flow meters, water quality sensors and calibration tools complete the range.

SSEA instruments by family

FamilySSEA productsStated figures
Pressure gaugesSRU 25, SRU 25X with mini diaphragm seal, SRU 35, SR 01; SRU25 chemical gauges in Hastelloy, Monel and Inconel; SRU15 and SR15 boiler gauges; PCU05 phenolic case gaugeSRU 25: -1 to 100 bar, special versions up to 1,600 bar; 1% fsd with the 100 mm dial
Test pressure gaugesSRU15 test gauge, SFU 15, SF 15250 mm dial
Gauge accessoriesSyphons, cooling tower, snubbers, overload protectors, gauge cocks, shut-off valve, 3-way, 3-valve and 5-valve manifolds, swivel adapter, max drag pointerSee product pages
Electrical pressurePTX-36 gauge transmitter, SSEA-PTIII transmitter, DTG200 digital gaugePTX-36: 4–20 mA, dial still reads in a power failure; DTG200: -1 to 2,500 bar
Pressure calibrationIDTG 100 pressure calibrator, HPCP-700 hydraulic comparison pumpIDTG 100: -1 to 600 bar
TemperatureSTU02 bimetallic and STU01 gas filled thermometers, STW bar-stock thermowellsSTU02 bimetal thermometer to EN 13190
Flow metersCMF VIII Coriolis, MFIII electromagnetic, VFIII vortex, SWFVI swirl, TMFIII thermal mass, OGMFIII oval gear, VAFIII variable area, WMIII, TFLIII and TFGIII turbine, UCOF and UFP-1.0 clamp-on ultrasonicSee product pages
Water qualityDigital sensors for pH, dissolved oxygen, conductivity, turbidity, suspended solids, COD, ammonia nitrogen, nitrate, free chlorine, oil in water, blue-green algae, transparency and colour; MPSX sonde, HMSX handheld meter, MPTX and DCCX controllersSee product pages

How to choose within the range

  • General industrial duty: the SRU 25, all stainless steel with an SS316L tube and socket.
  • Corrosive or viscous media: the SRU 25X with its mini diaphragm seal, or an SRU25 chemical gauge.
  • Pressure testing and reference readings: a 250 mm test gauge, or the DTG200 digital gauge.
  • A reading in the control room: the PTX-36 sends 4–20 mA and keeps its local dial.
  • Temperature on a dial: the STU02 bimetallic or STU01 gas filled thermometer, with an STW thermowell where the stem needs protection.

Service in Shah Alam

Common pressure and temperature gauges are kept in warehouse stock. Our trained technical staff calibrate pressure, temperature and flow instruments in-house and on site. Our diaphragm seal filling station, in Shah Alam since June 2016, assembles seals for gauges, switches and transmitters of any brand.

Send the medium, range and connection and we will match one of our SSEA instruments: send an enquiry. The full gauge line-up is on the pressure gauge page.