SSEA-TCOLX Transparency and Color Sensor

The Schmierer SEA SSEA-TCOLX Transparency and Color Sensors are advanced digital instruments designed for continuous, online water quality monitoring. Utilizing precise optical transmission and absorption methods, these RS-485 Modbus-compatible sensors feature integrated self-cleaning brushes and automatic turbidity compensation to provide accurate, long-term measurement of water clarity and apparent color without chemical reagents

SKU: SSEA-TCOLX Categories: ,
Description

Description

Schmierer SEA Color Sensors use the optical absorption method to monitor water quality online without requiring chemical reagents. Unlike sensors that measure reflected RGB values from solid objects, these digital industrial sensors measure light transmitted directly through water to assess color and transparency. They are suitable for monitoring drinking water, wastewater, and other water treatment processes.

Models

  • Y530-A Self-Cleaning Transparency Sensor: A digital optical probe designed to measure water transparency using the direct light transmission method. Its integrated cleaning mechanism helps reduce optical window fouling.
  • Y531-B Low-Range Color Sensor: A high-precision sensor designed for low color concentrations in treated drinking water, with a stated measurement range of 0–50 Hazen.
  • Y534-A Low-Range Color Sensor: A color measurement instrument designed for applications requiring standardized colorimetric monitoring in accordance with applicable ISO methods.

Features

  • Automatic Turbidity Compensation: Uses internal algorithms to compensate for interference caused by suspended particles, helping improve the reliability of color measurements.
  • Mechanical Self-Cleaning: An integrated motorized cleaning brush or wiper cleans the optical windows automatically, helping reduce biofouling and manual maintenance.
  • Smart Digital Architecture: Supports RS-485 communication using the Modbus protocol for integration with PLC and SCADA systems. Calibration parameters are stored within the probe.
  • Interference Compensation: Optical signal processing and turbidity compensation help reduce measurement errors caused by suspended particles.
  • Operating Conditions: The stated operating temperature range is 0–50°C, with a maximum operating pressure of 3 bar. Confirm the limits for the selected model before installation.
  • Ingress Protection: The stated IP68 enclosure rating supports submersible applications when installed according to the manufacturer’s requirements.

Working Principle

These optical sensors operate using the light absorption and transmission method. The probe emits a controlled light beam through a defined path length in the water. Dissolved substances, organic compounds, and natural color-causing materials absorb specific wavelengths of light, while the remaining light passes through the sample and reaches the receiver.

The sensor measures the transmitted light intensity and processes the optical signal to determine water transparency or color concentration. Color readings may be expressed in Hazen units, depending on the model and measurement method.

To improve measurement reliability, the sensor may apply internal compensation algorithms to reduce interference from turbidity and suspended particles. This enables continuous online monitoring without adding chemical reagents. Actual performance depends on the sensor design, water characteristics, calibration, and measurement conditions.

Applications

  • Drinking Water Infrastructure: Continuous monitoring of water color and transparency across municipal distribution networks, pumping stations, and treated water systems.
  • Effluent Compliance Monitoring: Monitoring the color and clarity of treated effluent at municipal and industrial wastewater treatment plants.
  • Groundwater Assessment: Tracking changes in water color and transparency in wells and groundwater monitoring systems.
  • Raw Water Intake Diagnostics: Monitoring seasonal changes in surface water quality to help treatment plants assess variations in incoming water.

Note: Verify each model’s measurement range, color scale, accuracy, communication settings, self-cleaning mechanism, and operating limits against the official manufacturer datasheet. Confirm the applicable ISO color measurement method for the intended application.

About SSEA

SSEA instruments are Schmierer SEA's own range, offered from Shah Alam and led by pressure gauges. The SRU 25 stainless steel pressure gauge uses a silicon-jelly stabiliser instead of liquid filling and is rated IP66. The STU02 bimetallic thermometer is built to EN 13190. Gauge accessories, flow meters, water quality sensors and calibration tools complete the range.

SSEA instruments by family

FamilySSEA productsStated figures
Pressure gaugesSRU 25, SRU 25X with mini diaphragm seal, SRU 35, SR 01; SRU25 chemical gauges in Hastelloy, Monel and Inconel; SRU15 and SR15 boiler gauges; PCU05 phenolic case gaugeSRU 25: -1 to 100 bar, special versions up to 1,600 bar; 1% fsd with the 100 mm dial
Test pressure gaugesSRU15 test gauge, SFU 15, SF 15250 mm dial
Gauge accessoriesSyphons, cooling tower, snubbers, overload protectors, gauge cocks, shut-off valve, 3-way, 3-valve and 5-valve manifolds, swivel adapter, max drag pointerSee product pages
Electrical pressurePTX-36 gauge transmitter, SSEA-PTIII transmitter, DTG200 digital gaugePTX-36: 4–20 mA, dial still reads in a power failure; DTG200: -1 to 2,500 bar
Pressure calibrationIDTG 100 pressure calibrator, HPCP-700 hydraulic comparison pumpIDTG 100: -1 to 600 bar
TemperatureSTU02 bimetallic and STU01 gas filled thermometers, STW bar-stock thermowellsSTU02 bimetal thermometer to EN 13190
Flow metersCMF VIII Coriolis, MFIII electromagnetic, VFIII vortex, SWFVI swirl, TMFIII thermal mass, OGMFIII oval gear, VAFIII variable area, WMIII, TFLIII and TFGIII turbine, UCOF and UFP-1.0 clamp-on ultrasonicSee product pages
Water qualityDigital sensors for pH, dissolved oxygen, conductivity, turbidity, suspended solids, COD, ammonia nitrogen, nitrate, free chlorine, oil in water, blue-green algae, transparency and colour; MPSX sonde, HMSX handheld meter, MPTX and DCCX controllersSee product pages

How to choose within the range

  • General industrial duty: the SRU 25, all stainless steel with an SS316L tube and socket.
  • Corrosive or viscous media: the SRU 25X with its mini diaphragm seal, or an SRU25 chemical gauge.
  • Pressure testing and reference readings: a 250 mm test gauge, or the DTG200 digital gauge.
  • A reading in the control room: the PTX-36 sends 4–20 mA and keeps its local dial.
  • Temperature on a dial: the STU02 bimetallic or STU01 gas filled thermometer, with an STW thermowell where the stem needs protection.

Service in Shah Alam

Common pressure and temperature gauges are kept in warehouse stock. Our trained technical staff calibrate pressure, temperature and flow instruments in-house and on site. Our diaphragm seal filling station, in Shah Alam since June 2016, assembles seals for gauges, switches and transmitters of any brand.

Send the medium, range and connection and we will match one of our SSEA instruments: send an enquiry. The full gauge line-up is on the pressure gauge page.