SYS-MMF Multivariable Transmitter

The SYS-MMF Multivariable Transmitter by systec Controls provides compensated flow measurement for industrial processes. It measures differential pressure and static pressure while using an external Pt100 temperature sensor to compensate for temperature changes. Moreover, it calculates mass flow or standard volume flow, depending on the configured fluid and application. Therefore, it helps simplify flow measurement while reducing installation costs and wiring requirements.

SKU: Deltaflow SYS-MMF Categories: ,
Description

Description

The SYS-MMF Multivariable Transmitter by systec Controls provides compensated flow measurement for industrial processes. It measures differential pressure and static pressure while using an external Pt100 temperature sensor to compensate for temperature changes. Moreover, it calculates mass flow or standard volume flow, depending on the configured fluid and application. Therefore, it helps simplify flow measurement while reducing installation costs and wiring requirements.

Models and Configurations -Multivariable Transmitter SYS-MMF

The SYS-MMF product range includes different measuring ranges to suit various process conditions.

  • SYS-MMF: Measures differential pressure, absolute pressure and temperature input for compensated flow measurement.
  • SYS-MTF: Measures differential pressure and accepts a temperature input without an internal absolute-pressure sensor. It is suitable for applications where pressure can be assumed constant, such as certain saturated-steam systems.

Measuring Range Options

Model Code Differential Pressure Range Absolute Pressure Range
BB 0–10 mbar 0–20 bar abs
BD 0–60 mbar 0–20 bar abs
DE 0–400 mbar 0–100 bar abs
DN / EDN 0–2500 mbar 0–250 bar abs

Confirm the exact ordering code and pressure rating with the manufacturer, as configurations and designations may vary by revision.

Key Specifications

  • Measurement Principle: Differential pressure with pressure and temperature compensation.

  • Measured Parameters: Differential pressure (DP), absolute pressure and temperature input.
  • Temperature Input: External three-wire Pt100 RTD.
  • Output Signal: Two-wire 4–20 mA, HART-capable as standard.
  • Communication: Optional Modbus interface.
  • Configurable Flow Values: Mass flow, standard volume flow or volume flow, depending on the application.
  • Totalization: Integrated flow totalizer.
  • Supported Fluids: Gases, saturated steam, superheated steam and compatible liquids.
  • Configuration: Three front-panel keys for straightforward parameterization.
  • Primary Elements: Compatible differential-pressure devices, including orifice plates, Venturi tubes, nozzles and Pitot-based flow probes.
  • Typical Mass-Flow Accuracy: Approximately 1% of full scale, plus the uncertainty of the primary element, under specified conditions.

Working Principle

The SYS-MMF uses the differential-pressure principle to determine flow. First, a primary element creates a pressure difference as fluid passes through the pipe. The transmitter measures this differential pressure, while its internal absolute-pressure sensor measures static pressure.

Next, an external Pt100 sensor supplies the fluid temperature. The transmitter uses these measurements and the configured fluid properties to compensate for changes in pressure and temperature. It then calculates the appropriate mass-flow or standard-volume-flow value and transmits the result through its output signal.

Consequently, the system can provide compensated flow measurement without requiring separate pressure and temperature transmitters for the same measurement arrangement.

Advantages

  • Multivariable Measurement: Combines differential-pressure and static-pressure measurement with temperature compensation.
  • Lower Installation Costs: Can reduce the need for separate transmitters, process connections and cabling.
  • Simplified Commissioning: Front-panel configuration reduces dependence on complex setup software.
  • Compensated Flow Measurement: Helps account for pressure and temperature changes.
  • Flexible Integration: Supports 4–20 mA and HART, with optional Modbus.
  • Multiple Primary Elements: Works with compatible differential-pressure flow devices.
  • Reduced Control-System Workload: Performs configured flow calculations within the transmitter rather than requiring all compensation calculations in a PLC.

Applications

The SYS-MMF is suitable for:

  • Steam mass-flow measurement
  • Compressed-air and industrial gas monitoring
  • Superheated and saturated steam systems
  • Water and compatible liquid flow measurement
  • Boiler and utility systems
  • Energy monitoring and consumption reporting
  • Process plants requiring compensated differential-pressure flow measurement

Conclusion

The SYS-MMF Multivariable Transmitter offers a practical solution for compensated flow measurement using the differential-pressure method. By combining pressure measurement and an external temperature input, it can simplify instrumentation and reduce installation complexity. Moreover, its flexible outputs and compatibility with several primary elements make it suitable for a wide range of industrial flow applications.

About Systec Controls

Products & Features

Systec Controls from Germany specializes in Differential Pressure (DP) and Ultrasonic Transit Time flow technologies for gas and steam. Their systems are designed for extreme industrial conditions, high temperatures, high pressures, and contaminated media.

Differential Pressure Technology (Deltaflow Series):
This technology uses the proven differential pressure principle, where a primary element (like a Pitot Tube or Venturi) creates a pressure drop proportional to the flow velocity.

Ultrasonic Transit Time Technology (Deltawave Series):
This technology measures the time difference between ultrasonic signals traveling with and against the flow direction. It is virtually maintenance-free as it has no moving parts or pressure loss.

Key Benefits

  • Cost Savings: Clamp-on technology saves significantly on installation time and operating costs, as there is no need to interrupt the process.
  • Low Energy Consumption: The deltaflow system is designed to have very low pressure losses, resulting in energy savings.
  • Long-Term Reliability and Robustness: designed for longevity, robust sensors against fouling (soiling).100% Maintenance free clamp on ultrasonic systems
  • Optimized DP Technology: lowest pressure loss with high precision
  • Easy Installation and a uniform display concept for both portable and permanently mounted devices.