deltaflowC2 Gas Flow Meter

The systec Controls deltaflowC2 Gas Flow Meter measures gas mass flow using the differential pressure (DP) principle. It combines differential pressure, static pressure and temperature sensors with an integrated processor. As a result, it calculates compensated gas mass flow while also providing pressure and temperature data.

Moreover, the deltaflowC2 handles rapidly changing flow conditions and pulsating gas flows. Therefore, it is particularly suitable for compressed air systems, compressor monitoring, ventilation and industrial gas-flow control.

SKU: Deltaflow C Categories: ,
Description

Description

Models and Configurations

The deltaflowC2 is available in two main configurations:

1. Insertion Probe Version

The insertion probe is designed for pipes with an internal diameter of approximately DN32 and larger. It extends into the pipeline to measure the pressure difference created by the flowing gas.

Consequently, it provides a practical solution for larger pipes and ducts without requiring a full-bore flow meter.

2. Screw-In Venturi Version

The screw-in Venturi version is designed for smaller pipelines, typically around 3/4 to 1.5 inches. It uses a compact Venturi measuring section to create a differential pressure.

Therefore, it is suitable for compressed air distribution lines and other smaller gas-flow applications.

Key Specifications

  • Manufacturer: systec Controls
  • Measurement Principle: Differential pressure (DP)
  • Measured Variables: Differential pressure, static pressure and temperature
  • Calculated Values: Gas mass flow and volume flow, depending on configuration
  • Measurement Speed: Up to 2,000 measurements per second
  • Analog Outputs: 4–20 mA and 0–10 V DC
  • Digital Communication: Modbus RTU and CAN bus, depending on configuration
  • Additional Output: Pulse output, depending on configuration
  • Power Supply: 18–36 V DC
  • Wetted Measuring-Element Material: Stainless steel 1.4571, according to the manufacturer’s published specifications
  • Housing Material: Stainless steel, depending on the version
  • Typical Applications: Compressed air, ventilation air, combustion air and other compatible gases

Note: Maximum operating pressure, temperature limits, output availability and material specifications depend on the selected version. Check the latest manufacturer datasheet before ordering.

Working Principle

The deltaflowC2 measures gas flow through differential pressure. However, the measuring method differs slightly between the insertion probe and Venturi versions.

Insertion Probe: As gas passes the probe, it creates a pressure difference between the upstream-facing and downstream-facing openings. This differential pressure indicates the local gas velocity.

Venturi Version: Gas accelerates through a narrowed section of the measuring element. The pressure difference between the inlet and throat provides a measurement related to flow velocity.

Next, the integrated sensors measure static pressure and gas temperature. The electronics use these values, together with the configured gas properties and pipeline dimensions, to determine gas density and calculate compensated mass flow.

As a result, the deltaflowC2 can respond to changes in pressure and temperature rather than relying on differential pressure alone.

Advantages

  • Multivariable Measurement: Measures differential pressure, static pressure and temperature in one compact device.
  • Compensated Gas Flow: Accounts for pressure and temperature changes when calculating mass flow.
  • Fast Response: Processes measurements at up to 2,000 measurements per second.
  • Suitable for Pulsating Flows: Supports demanding applications involving compressors and engine test benches.
  • Low Maintenance Requirements: Its measuring principle and integrated compensation help reduce sensitivity to sensor-surface contamination and long-term drift.
  • Flexible Integration: Provides analog signals and optional digital communication for automation systems.
  • Adaptable Installation: Insertion and Venturi versions suit different pipeline sizes.
  • Flexible Gas Configuration: The configured gas can be changed using the appropriate parameter settings and calculation method, subject to application limits.

Applications

The systec Controls deltaflowC2 is suitable for:

  • Compressed air flow measurement
  • HVAC and ventilation systems
  • Compressor monitoring and control
  • Combustion air regulation
  • Industrial process air management
  • Pneumatic systems
  • Exhaust gas measurement in compatible applications
  • Engine and compressor test benches
  • Industrial energy monitoring

Installation and Selection

First, identify the gas composition and confirm that it is compatible with the meter. Next, check the pipeline diameter, operating pressure and temperature. Then, choose either the insertion probe or screw-in Venturi configuration.

In addition, confirm the required output signals and communication protocols before connecting the instrument to a PLC, DCS or energy monitoring system. Correct parameterization is essential because the meter uses the configured gas properties and installation dimensions to calculate flow.

Conclusion

The systec Controls deltaflowC2 is a compact gas mass flow meter that combines differential pressure, pressure and temperature measurement. Its fast measurement capability makes it suitable for both steady and pulsating gas flows. Moreover, its insertion and Venturi configurations provide installation flexibility for different pipeline sizes.

Consequently, it offers a practical solution for compressed air monitoring, ventilation control and industrial gas-flow measurement where compensated flow data is important.

About Systec Controls

Products & Features

Systec Controls from Germany specializes in Differential Pressure (DP) and Ultrasonic Transit Time flow technologies for gas and steam. Their systems are designed for extreme industrial conditions, high temperatures, high pressures, and contaminated media.

Differential Pressure Technology (Deltaflow Series):
This technology uses the proven differential pressure principle, where a primary element (like a Pitot Tube or Venturi) creates a pressure drop proportional to the flow velocity.

Ultrasonic Transit Time Technology (Deltawave Series):
This technology measures the time difference between ultrasonic signals traveling with and against the flow direction. It is virtually maintenance-free as it has no moving parts or pressure loss.

Key Benefits

  • Cost Savings: Clamp-on technology saves significantly on installation time and operating costs, as there is no need to interrupt the process.
  • Low Energy Consumption: The deltaflow system is designed to have very low pressure losses, resulting in energy savings.
  • Long-Term Reliability and Robustness: designed for longevity, robust sensors against fouling (soiling).100% Maintenance free clamp on ultrasonic systems
  • Optimized DP Technology: lowest pressure loss with high precision
  • Easy Installation and a uniform display concept for both portable and permanently mounted devices.