SWIRL FLOW METER SSEA-SWFVI

The Schmierer SEA SSEA Swirl Flow Meter (SSEASWFVI) measures the flow of gases, steam and low-viscosity liquids using the swirl precession principle. Its internal swirl-generating element creates a controlled rotating flow pattern, allowing the meter to determine flow rate from the resulting pressure oscillations.

Moreover, the SSEA Swirl Flow Meter requires relatively short straight pipe sections. With no moving parts, it also offers low maintenance requirements and stable performance. Therefore, it is a practical solution for industrial plants that need reliable flow measurement in space-constrained piping systems.

SKU: SSEASWFVI Categories: ,
Description

Description

Schmierer SEA SSEA Swirl Flow Meter – High-Accuracy Flow Measurement for Gas, Steam and Liquids

 

Models and Configurations

The SSEASWFVI is the SSEA Enhanced Swirl Flow Meter listed in the Schmierer SEA product catalogue. Configuration options can be selected according to the process medium, operating conditions and installation requirements.

  • SSEASWFVI Enhanced Swirl FlowmeterStandard configuration: For compatible gases, liquids and steam under specified operating conditions.
  • High-temperature configuration: Extended-temperature versions are available for demanding steam applications.
  • Material options: Carbon steel, SS304 and SS316L body options, with alternative sensor materials for compatible applications.
  • Output options: Analog and pulse outputs, with optional digital communication.
  • Compensated measurement: Optional pressure and temperature inputs can support mass-flow or standard-volume-flow calculations.

Key Specifications

  • Product name: SSEA Enhanced Swirl Flow Meter
  • Model / SKU: SSEASWFVI
  • Measurement principle: Swirl precession
  • Measured media: Liquids, gases, saturated steam and superheated steam
  • Accuracy for liquids: Typically ±0.5% of rate under calibrated conditions
  • Accuracy for gases and steam: Typically ±1.0% of rate under calibrated conditions
  • Turndown ratio: Up to 1:20, depending on the medium and installation
  • Minimum flow velocity: As low as approximately 0.5 m/s, depending on the application
  • Straight pipe requirements: Typically 3 × DN upstream and 1 × DN downstream
  • Standard temperature capability: Up to 250°C
  • Optional temperature capability: Up to 400°C for extended-temperature steam versions
  • Pressure ratings: 1.6 MPa, 2.5 MPa or 4.0 MPa, depending on the model
  • Body and flange materials: Carbon steel, SS304 or SS316L
  • Sensor wetted materials: SS304, SS316L, Hastelloy C, Hastelloy B or titanium, depending on configuration
  • Sensor type: Piezoelectric
  • Outputs: 4–20 mA and pulse
  • Communication: HART and Modbus RTU options
  • Design: No moving parts and a fully welded flow path

Working Principle

The SSEA Swirl Flow Meter operates using the principle of vortex precession.

Step 1 – Create a swirling flow. As the fluid enters the meter, a fixed internal swirl element forces it into rotational movement. This creates a primary vortex within the measuring section.

Step 2 – Generate vortex precession. As the swirling fluid moves through the expanded section, the vortex core begins to precess around the central axis. The resulting oscillation frequency changes with the volumetric flow rate.

Step 3 – Detect the signal. An integrated piezoelectric sensor detects the pressure oscillations and converts them into an electrical signal.

Step 4 – Calculate flow. The electronics process the signal to determine the flow rate. With suitable pressure and temperature compensation, the system can also calculate mass flow or standard volume flow.

Consequently, the meter provides a repeatable flow measurement without relying on moving mechanical components.

Advantages

  • High measurement accuracy: Typical accuracy reaches ±0.5% for liquids and ±1.0% for gases and steam under specified calibrated conditions.
  • Short installation lengths: Typical straight-run requirements of 3D upstream and 1D downstream help save piping space.
  • Low-flow capability: Suitable configurations can measure flow velocities as low as approximately 0.5 m/s.
  • Vibration and interference resistance: Digital signal processing helps improve signal stability in demanding environments.
  • Low maintenance: The absence of moving parts reduces mechanical wear.
  • Corrosion-resistant options: Stainless steel and special sensor materials support compatible process media.
  • High-temperature operation: Optional versions support demanding steam applications.
  • Automation integration: Analog outputs and optional digital communication simplify PLC and DCS integration.
  • Flexible flow calculations: Optional pressure and temperature compensation supports more advanced flow measurement.

SSEASWFVI Enhanced Swirl Flowmeter Overview

Applications

The Schmierer SEA SSEA Swirl Flow Meter is suitable for:

  • Steam flow measurement and energy monitoring
  • Industrial gas flow measurement
  • Compressed air systems
  • Nitrogen blanketing
  • Biogas measurement
  • Compressed natural gas (CNG) applications
  • Hydrogen flow measurement, subject to material and application compatibility
  • Chemical and petrochemical processing
  • Power generation and boiler systems
  • Industrial utility monitoring
  • Process control and consumption monitoring

Installation and Selection

First, identify the process medium and its operating conditions. Next, select a suitable meter size based on the expected minimum, normal and maximum flow rates. This is particularly important because the turndown ratio and minimum measurable flow depend on the application.

Then, confirm the pressure rating, temperature limit, body material and sensor wetted materials. In addition, allow the recommended straight pipe lengths—typically 3D upstream and 1D downstream—and assess any upstream disturbances that could affect the measurement.

Finally, choose the appropriate output and communication options. If the application requires mass flow or standard-volume flow, confirm whether pressure and temperature compensation are included in the selected configuration.

Conclusion

The Schmierer SEA SSEA Swirl Flow Meter provides industrial flow measurement for gases, steam and low-viscosity liquids. Its swirl precession principle, short straight-run requirements and moving-part-free design make it suitable for demanding installations where space and maintenance are important considerations.

Moreover, optional pressure and temperature compensation, combined with flexible output options, supports integration into modern industrial automation and energy monitoring systems.

About SSEA

SSEA instruments are Schmierer SEA's own range, offered from Shah Alam and led by pressure gauges. The SRU 25 stainless steel pressure gauge uses a silicon-jelly stabiliser instead of liquid filling and is rated IP66. The STU02 bimetallic thermometer is built to EN 13190. Gauge accessories, flow meters, water quality sensors and calibration tools complete the range.

SSEA instruments by family

FamilySSEA productsStated figures
Pressure gaugesSRU 25, SRU 25X with mini diaphragm seal, SRU 35, SR 01; SRU25 chemical gauges in Hastelloy, Monel and Inconel; SRU15 and SR15 boiler gauges; PCU05 phenolic case gaugeSRU 25: -1 to 100 bar, special versions up to 1,600 bar; 1% fsd with the 100 mm dial
Test pressure gaugesSRU15 test gauge, SFU 15, SF 15250 mm dial
Gauge accessoriesSyphons, cooling tower, snubbers, overload protectors, gauge cocks, shut-off valve, 3-way, 3-valve and 5-valve manifolds, swivel adapter, max drag pointerSee product pages
Electrical pressurePTX-36 gauge transmitter, SSEA-PTIII transmitter, DTG200 digital gaugePTX-36: 4–20 mA, dial still reads in a power failure; DTG200: -1 to 2,500 bar
Pressure calibrationIDTG 100 pressure calibrator, HPCP-700 hydraulic comparison pumpIDTG 100: -1 to 600 bar
TemperatureSTU02 bimetallic and STU01 gas filled thermometers, STW bar-stock thermowellsSTU02 bimetal thermometer to EN 13190
Flow metersCMF VIII Coriolis, MFIII electromagnetic, VFIII vortex, SWFVI swirl, TMFIII thermal mass, OGMFIII oval gear, VAFIII variable area, WMIII, TFLIII and TFGIII turbine, UCOF and UFP-1.0 clamp-on ultrasonicSee product pages
Water qualityDigital sensors for pH, dissolved oxygen, conductivity, turbidity, suspended solids, COD, ammonia nitrogen, nitrate, free chlorine, oil in water, blue-green algae, transparency and colour; MPSX sonde, HMSX handheld meter, MPTX and DCCX controllersSee product pages

How to choose within the range

  • General industrial duty: the SRU 25, all stainless steel with an SS316L tube and socket.
  • Corrosive or viscous media: the SRU 25X with its mini diaphragm seal, or an SRU25 chemical gauge.
  • Pressure testing and reference readings: a 250 mm test gauge, or the DTG200 digital gauge.
  • A reading in the control room: the PTX-36 sends 4–20 mA and keeps its local dial.
  • Temperature on a dial: the STU02 bimetallic or STU01 gas filled thermometer, with an STW thermowell where the stem needs protection.

Service in Shah Alam

Common pressure and temperature gauges are kept in warehouse stock. Our trained technical staff calibrate pressure, temperature and flow instruments in-house and on site. Our diaphragm seal filling station, in Shah Alam since June 2016, assembles seals for gauges, switches and transmitters of any brand.

Send the medium, range and connection and we will match one of our SSEA instruments: send an enquiry. The full gauge line-up is on the pressure gauge page.