WATERSENS Water Flood Detector & Level Warning Sensor

Secure your facility against devastating liquid damage, structural flooding, and critical reservoir failures. Commercial property managers, automation technicians, and plant engineers deploy the Ensim WATERSENS series to achieve high-performance early leak detection and level warning control. Because this highly sensitive electronic switch triggers instantly when fluid interfaces complete its specialized non-electrolysis circuit path, it completely eliminates tracking delays common to slower mechanical floats. Consequently, your facility gains continuous, worry-free flood mitigation that can immediately shut down upstream solenoid water valves or sound alarms before costly property loss occurs.

SKU: Watersens Category:
Description

Description

Product Types

The specialized moisture tracking platform configures dynamically across dedicated functional formats to protect distinct property rooms, open floor plans, and tank configurations:

  • WATERSENS Standard Leak Detector: Powered efficiently by a standalone 9V battery or external line source, built for floor-level placement in technical spaces to spot floods early.
  • WATERSENS P / N / R Facility Series: Engineered specifically to determine high-water or low-water levels inside industrial vessels, balancing pits, and storage basins.
  • Integrated Valve Controller Setup: Outfitted with dedicated relay outputs configured to command an external solenoid safety valve to isolate water lines instantly upon moisture detection.

Working Principle

The device operates using advanced conductive liquid detection coupled with a specialized anti-electrolysis circuit design. The submersion probe houses premium stainless steel electrode pins that rest completely open under dry conditions. When an incoming flood layer or rising tank level bridges the gap between these terminals, the conductive liquid completes a low-voltage electrical loop path. The electronic card, securely insulated with protective resin inside the upper enclosure box, instantly identifies this resistance drop. To protect wetted lead components from degradation, the module utilizes a specialized electrical design that entirely prevents terminal electrolysis. Finally, the system engages an integrated loud siren and triggers the relay output loops immediately.

Key Specs

Technical Parameter Manufacturer Specification
Measurement Technology Conductive Electrode Sensing (Anti-Electrolysis Matrix)
Power Supply Options 9V Battery block (Mobile version) or standard industrial power grids
Electrode Pin Metallurgy Premium Corrosion-Resistant Stainless Steel
Electronic Protection Resin-encapsulated upper control box (100% moisture immune)
Output Configuration Integrated high-decibel audible siren alarm & hardwired relay contact
Probe Mounting Option Equipped with a molded submersion tooth to securely anchor sinker weights

Advantages

  • Anti-Electrolysis Sensor Core: The specialized electronic signal design prevents terminal breakdown during continuous submersion. As a result, you eliminate probe degradation and maintain pristine alert stability over years of service.
  • Resin-Insulated Waterproof Card: Encapsulating the upper electronic board in premium resin blocks ambient moisture completely. Therefore, your sensor remains perfectly protected from failure even when deployed inside damp, steaming generator rooms.
  • Direct Solenoid Interlock Safety: The built-in relay output commands automated shutoff equipment directly. Consequently, your facility minimizes flood spread by closing supply lines the exact second a leak breaks out.
  • Submersion Weight Optimization: The molded mechanical tooth configuration anchors heavy line weights cleanly. As a result, your engineering crew easily sets custom probe depths inside deep collection pits without risking line drift.

Applications

Building safety and process engineers position the highly responsive Ensim WATERSENS detectors across critical utility spaces:

  • Server & Computer Rooms: Safeguards sensitive data grids, technical floor voids, and telecom centers against sudden air conditioner condensate leaks.
  • Industrial Compressor Rooms: Monitors background oil/water separator lines and compressor collection trays to alert operators to system breaks.
  • Commercial Warehouses: Delivers heavy-duty floor-level flood warning alerts around vulnerable ingredient inventories and chemical stacks.
  • Generator & Boiler Rooms: Tracks passive pipeline leaks, utility floor sumps, and secondary containment areas cleanly and reliably.
About Ensim

Products & Features

Ensim Sensors from Turkiye provides a variety of level, flow, pressure and temperature instruments for liquids, solids and powders designed for demanding industrial environments in explosive environments for point detection (switches) or continuous monitoring (transmitters):
  • Radar Level: non-contact and guided wave sensors
  • Capacitive Level Sensors:
  • Magnetic By-pass and Visual Indicators
  • Hydrostatic
  • Ultrasonic
  • Magnetic Float 
  • Rotary Paddle, Vibrating Fork/Rod 
  • Flow Switches

Key Benefits

  • Rugged Construction, Reliability, Low Maintenance
  • Advanced Level Sensing: in dusty, humid, or smoky environments
  • Easy Integration: Designed for quick commissioning and simple installation into existing processes.Â