Pressure
Temperature
Bimetallic
1 product
TC
0 products
Gas filled
4 products
Thermowell
0 products
Ceramic Protection Tube
2 products
Replaceable measuring inserts
7 products
Non-Replaceable Measuring Inserts
3 products
Surface and Machinery Sensors
35 products
For Food and Pharmaceutical Industry
7 products
For HVAC Applications
9 products
For Acids, Alkalis, and Salts
4 products
Flameproof and Intrinsically Safe
5 products
Transmitters and Accessories
18 products
Accessories
0 products
Flowmeter
Electro Magnetic
0 products
Vortex
11 products
Swirl
0 products
Ultrasonic
2 products
Positive Displacement
6 products
Variable Area
0 products
Differential Pressure
9 products
Gas Turbine
0 products
Flap
0 products
Side Glass
0 products
Thermal gas
0 products
Level
Radar
6 products
Ultrasonic
0 products
Capacitance
13 products
Conductivity
0 products
Magnetic
0 products
Float
0 products
Buoyancy
0 products
Tube
0 products
Vibrating Rod
0 products
Rotary Paddle
0 products
Level Switches
27 products
Analytical
Concentration
0 products
Density
0 products
Chlorine
0 products
Conductivity
5 products
PH
0 products
Redox
0 products
Calibration Devices
Multi Function Calibrators
0 products
Pressure Calibrators
0 products
Temperature Calibrators
0 products
Valve Testing
0 products
All products
VA Flow Meter for acidic chemicals, high temp. and pressure
The SGM gas and liquid flow meter series from Kirchner works on the variable area float principle. It provides instantaneous values for gas and liquid flow monitoring in pipelines with high temperature, pressure and highly acidic chemical liquids with low pressure loss.
- Accuracy: ±1.6%
- Low Pressure Loss
- Indication via Magnetic Coupling
- Individually calibrated to customer requirements – fitted with a medium specific scale
Â
SGM Product Range & Applications
Â
SS Version – for high temperature and pressure applications
Size: DN 15, 25, 50, 80, 100 (opt. ANSI or JIS)
Max Pressure: PN 40 – PN16 (for DN 80, 100)
opt. stainless steel with PTFE or TMF liner and ceramics    download PDF
- SGM/VA stainless steel, media temperature -196 to 300°C
- SGM/C4 Hastelloy C4, media temperature -196 to 300°CÂ
Â
Cost effective fully plastic Version – for chemical applications
with highly acidic media, e.g. hydrochloric acid
Size: DN 25, 50, 65, 80, 100 (opt. ANSI or JIS)
Max Pressure: PN 16 – PN10 (for DN 65, 80, 100)Â Â Â Â Â Â download PDF
- SGM/PP Polypropylene, up to 80°C
- SGM/PVC Polyvinylchloride, up to 40°C
Options:
- Limit value switches
- Analog output 4 to 20 mA
- Explosion proof design and output (EEx) for VA and C4 version
- Horizontal installation