SSEA-MFIII Electromagnetic Flow Meter

The Schmierer SEA SSEAMFIII Electromagnetic Flow Meter measures the volumetric flow rate of electrically conductive liquids in industrial pipelines. It uses Faraday’s law of electromagnetic induction to determine liquid velocity and calculate flow. As a result, it provides reliable flow measurement without placing moving mechanical parts in the flow path.

The SSEAMFIII is designed for applications involving water, wastewater, sludge, and compatible chemical liquids. Moreover, its range of liner materials, electrode options, and process connections allows users to select a configuration for different operating conditions. Therefore, it is suitable for many water treatment, chemical processing, and industrial liquid measurement applications.

SKU: SSEA MFIII Categories: ,
Description

Description

Types

Key Features

  • Electromagnetic measurement: Uses Faraday’s law to measure the flow of conductive liquids.
  • No moving parts: Reduces mechanical wear and helps simplify routine maintenance.
  • Low pressure loss: Provides an unobstructed measuring passage without a moving rotor or turbine.
  • Multiple liner materials: Offers rubber, PTFE, and PFA options, depending on the application.
  • Electrode selection: Available electrode materials include SS316, titanium, tantalum, Hastelloy C, and platinum-iridium.
  • Flexible connections: Supports flange, sanitary, and insertion configurations.
  • Signal integration: Supports 4–20 mA and pulse outputs, with communication options including RS485 and HART.
  • Flexible configurations: Manufacturer listings include compact and remote versions, battery-powered variants, and ATEX options.

Working Principle

The SSEAMFIII operates according to Faraday’s law of electromagnetic induction. When an electrically conductive liquid moves through a magnetic field, it generates a voltage proportional to its velocity.

Inside the flow meter, electromagnetic coils create a magnetic field across the measuring tube. As the liquid passes through this field, electrodes detect the induced voltage. The transmitter then processes the signal to determine the average liquid velocity.

Next, the instrument combines the calculated velocity with the pipe’s cross-sectional area to determine volumetric flow rate. Consequently, the meter can provide flow readings and, when configured accordingly, accumulated volume measurements.

Because the meter has no moving parts, it avoids the mechanical wear associated with turbine and other rotating-element meters. However, the liquid must have sufficient electrical conductivity, and the meter must be installed according to the manufacturer’s requirements for reliable measurement.

Technical Specifications

  • Manufacturer: Schmierer SEA
  • Model: SSEAMFIII
  • Product type: Electromagnetic flow meter
  • Measurement principle: Faraday’s law of electromagnetic induction
  • Measuring medium: Electrically conductive liquids, including compatible water-based fluids, wastewater, sludge, and chemicals
  • Accuracy options: ±0.2% or ±0.5% of reading, according to the product listing and selected configuration
  • Liner materials: Rubber, PTFE, PFA
  • Electrode materials: SS316, titanium, tantalum, Hastelloy C, platinum-iridium
  • Process connections: Flange, sanitary, insertion
  • Fluid temperature: -20°C to +180°C, depending on the selected liner and configuration
  • Signal outputs: 4–20 mA, pulse
  • Communication options: RS485, HART, GPRS, depending on the selected version
  • Power supply options: 110–240 V AC, 24 V DC, or battery, depending on the version
  • Protection rating: IP65 to IP68, depending on the configuration
  • Explosion protection: ATEX options listed by the manufacturer; confirm the applicable certification for the selected model
  • Nominal diameter and pressure rating: Confirm with the manufacturer for the required configuration

Note: Specifications vary by model configuration. In particular, verify the maximum temperature for the selected liner, the electrode material’s chemical compatibility, and the applicable protection and certification ratings before ordering.

Applications

  • Water and wastewater treatment: Measures flow in water distribution networks, sewage systems, treatment plants, and sludge lines.
  • Chemical processing: Monitors compatible conductive acids, alkalis, and chemical solutions.
  • Mining and minerals: Supports flow measurement for compatible slurries and liquids containing solids.
  • Pulp and paper: Measures suitable process liquids, pulp, pastes, and additives.
  • Food and beverage: Supports liquid flow measurement in compatible hygienic applications when the selected connection and materials meet sanitary requirements.
  • Industrial utilities: Helps monitor conductive process water and other compatible liquids.

 El Magnetiic FM Applications

Benefits of the SSEAMFIII Electromagnetic Flow Meter

Reduced mechanical maintenance: The absence of moving parts reduces wear within the measuring tube. As a result, the meter can help simplify maintenance in suitable applications.

Minimal flow obstruction: The open measuring passage creates very little additional pressure loss, helping preserve the hydraulic performance of the process system.

Suitable for challenging liquids: With the correct liner and electrode materials, the meter can handle compatible wastewater, sludge, and corrosive liquids.

Easy control system integration: The available 4–20 mA, pulse, and communication options support integration with compatible PLCs, DCS platforms, and monitoring systems.

Flexible configuration: Different connection styles, materials, and power options help users match the instrument to their process and installation requirements.

Conclusion

The Schmierer SEA SSEAMFIII Electromagnetic Flow Meter provides volumetric flow measurement for conductive liquids without moving parts. Its material options and industrial signal interfaces make it suitable for a broad range of compatible applications. Before selecting a model, confirm liquid conductivity, chemical compatibility, flow range, pressure rating, temperature limits, and the required connection type.

About SSEA

SSEA instruments are Schmierer SEA's own range, offered from Shah Alam and led by pressure gauges. The SRU 25 stainless steel pressure gauge uses a silicon-jelly stabiliser instead of liquid filling and is rated IP66. The STU02 bimetallic thermometer is built to EN 13190. Gauge accessories, flow meters, water quality sensors and calibration tools complete the range.

SSEA instruments by family

FamilySSEA productsStated figures
Pressure gaugesSRU 25, SRU 25X with mini diaphragm seal, SRU 35, SR 01; SRU25 chemical gauges in Hastelloy, Monel and Inconel; SRU15 and SR15 boiler gauges; PCU05 phenolic case gaugeSRU 25: -1 to 100 bar, special versions up to 1,600 bar; 1% fsd with the 100 mm dial
Test pressure gaugesSRU15 test gauge, SFU 15, SF 15250 mm dial
Gauge accessoriesSyphons, cooling tower, snubbers, overload protectors, gauge cocks, shut-off valve, 3-way, 3-valve and 5-valve manifolds, swivel adapter, max drag pointerSee product pages
Electrical pressurePTX-36 gauge transmitter, SSEA-PTIII transmitter, DTG200 digital gaugePTX-36: 4–20 mA, dial still reads in a power failure; DTG200: -1 to 2,500 bar
Pressure calibrationIDTG 100 pressure calibrator, HPCP-700 hydraulic comparison pumpIDTG 100: -1 to 600 bar
TemperatureSTU02 bimetallic and STU01 gas filled thermometers, STW bar-stock thermowellsSTU02 bimetal thermometer to EN 13190
Flow metersCMF VIII Coriolis, MFIII electromagnetic, VFIII vortex, SWFVI swirl, TMFIII thermal mass, OGMFIII oval gear, VAFIII variable area, WMIII, TFLIII and TFGIII turbine, UCOF and UFP-1.0 clamp-on ultrasonicSee product pages
Water qualityDigital sensors for pH, dissolved oxygen, conductivity, turbidity, suspended solids, COD, ammonia nitrogen, nitrate, free chlorine, oil in water, blue-green algae, transparency and colour; MPSX sonde, HMSX handheld meter, MPTX and DCCX controllersSee product pages

How to choose within the range

  • General industrial duty: the SRU 25, all stainless steel with an SS316L tube and socket.
  • Corrosive or viscous media: the SRU 25X with its mini diaphragm seal, or an SRU25 chemical gauge.
  • Pressure testing and reference readings: a 250 mm test gauge, or the DTG200 digital gauge.
  • A reading in the control room: the PTX-36 sends 4–20 mA and keeps its local dial.
  • Temperature on a dial: the STU02 bimetallic or STU01 gas filled thermometer, with an STW thermowell where the stem needs protection.

Service in Shah Alam

Common pressure and temperature gauges are kept in warehouse stock. Our trained technical staff calibrate pressure, temperature and flow instruments in-house and on site. Our diaphragm seal filling station, in Shah Alam since June 2016, assembles seals for gauges, switches and transmitters of any brand.

Send the medium, range and connection and we will match one of our SSEA instruments: send an enquiry. The full gauge line-up is on the pressure gauge page.