SSEA-UCOF Ultrasonic Clamp-On fixed Flow Meter

The Schmierer SEA SSEA-UCOF Ultrasonic Clamp-On Flow Meter measures liquid flow without requiring direct contact between the sensor and the process liquid. Its clamp-on ultrasonic transducers mount on the outside of the pipe. Therefore, installation does not require cutting the pipeline or stopping the flow.

The SSEA-UCOF uses digital signal processing technology to measure liquid flow across a wide range of pipe sizes. In addition, its wall-mounted transmitter, backlit LCD, and multiple output options support industrial monitoring and control. The meter also offers data logging capability through the manufacturer’s FlowData software, making it useful for flow monitoring, system verification, and process optimization.

SKU: SSEA UCOF Categories: ,
Description

Description

Key Features

  • Non-invasive measurement: Clamp-on transducers install outside the pipe, so there is no need to cut the pipeline.
  • Wide pipe size range: Supports pipe diameters from 25 mm to 5000 mm, depending on installation requirements.
  • Broad flow velocity range: Measures flow velocities from 0 to ±12 m/s according to the product brochure.
  • Multiple outputs: Provides 4–20 mA, OCT pulse, and relay outputs for compatible monitoring and control systems.
  • Digital communication: RS-485 communication with Modbus protocol supports integration with compatible systems.
  • Backlit LCD: The 20 × 2-character display helps operators view measurement information in different lighting conditions.
  • Data logging: Supports data logging with the manufacturer’s FlowData software.
  • Industrial construction: The transmitter uses an IP65-rated, die-cast aluminum enclosure.
  • Low maintenance: The design has no moving parts, reducing mechanical wear.
  • Bidirectional measurement: The meter supports measurement of flow in both directions when configured appropriately.

Working Principle

The SSEA-UCOF uses ultrasonic signals to measure the flow velocity of liquid inside a pipe. Its transducers attach to the pipe’s outer surface and transmit and receive ultrasonic signals through the pipe wall and liquid.

The transmitter processes the received signals to determine liquid flow velocity. It then uses the configured pipe dimensions and other measurement parameters to calculate the flow rate. Because the transducers remain outside the pipe, the meter avoids direct contact with the liquid and does not introduce an obstruction into the flow path.

As a result, the SSEA-UCOF can measure flow without interrupting normal pipeline operation for sensor installation. However, technicians must select a suitable measurement location and install the transducers according to the manufacturer’s instructions to achieve reliable readings.

Technical Specifications

  • Product name: SSEA-UCOF Ultrasonic Clamp-On Flow Meter
  • Instrument type: Dedicated ultrasonic flowmeter
  • Installation method: Wall-mounted transmitter with clamp-on transducers
  • Flow velocity range: 0 to ±12 m/s (0 to ±40 ft/s)
  • Accuracy: 2–3% of measured value within the specified velocity range of approximately ±0.5 to ±5 m/s
  • Repeatability: 0.15%
  • Pipe size range: 25 mm to 5000 mm (approximately 1 to 200 inches)
  • Display: Backlit 20 × 2-character alphanumeric LCD
  • Keyboard: 16 touch keys arranged in a 4 × 4 layout
  • Power supply: 90–250 VAC, 48–63 Hz, according to the specifications table
  • Transmitter enclosure: IP65-rated, die-cast aluminum enclosure
  • Analog output: 4–20 mA DC
  • Pulse output: OCT pulse output
  • Relay output: Available
  • Communication: RS-485 with Modbus protocol
  • Transducer operating temperature: -40°C to +120°C
  • Standard transducer cable length: 10 m (approximately 33 ft)
  • Data logging: Supported through FlowData software

Transducer Mounting Methods

  • V method: The brochure identifies this as the standard mounting method. It is generally used for pipe diameters of approximately 25 mm to 400 mm.
  • Z method: This method is intended for larger pipes, approximately 100 mm to 3000 mm. The brochure recommends considering the Z method for pipe diameters above 300 mm.

Choosing the correct mounting method helps improve signal quality and measurement reliability. In addition, technicians should account for nearby bends, tees, reducers, valves, pumps, and other pipe features when selecting the installation location.

Applications

  • Water and wastewater: Monitor flow in water supply networks, wastewater systems, and treatment plants.
  • Heating and cooling systems: Measure hot-water and chilled-water flow to support system monitoring and efficiency improvements.
  • Industrial process control: Monitor compatible liquid processes in chemical plants, steel plants, power plants, and manufacturing facilities.
  • Oil and fuel transfer: Measure suitable liquids such as fuel oil, diesel, crude oil, and lubricants, subject to application compatibility.
  • Water management: Support flow monitoring in buildings, irrigation systems, and municipal water networks.
  • Desalination plants: Monitor liquid flow in compatible desalination processes.
  • Food and pharmaceutical processing: Support non-invasive flow measurement where the installation and process requirements permit clamp-on measurement.
  • Leak detection and remote monitoring: Provide flow data for compatible monitoring networks and system assessments.
  • Retrofit projects: Add flow measurement to existing pipelines without installing an in-line meter.

These applications are based on the uses identified in the manufacturer’s brochure. Actual suitability depends on the liquid, pipe material, pipe condition, temperature, and installation requirements.

Benefits of the Schmierer SEA SSEA-UCOF

  • Reduced installation costs: Clamp-on transducers eliminate the need to cut the pipe for sensor installation.
  • Minimal process interruption: Technicians can install the sensors without stopping the liquid flow, provided the installation conditions are suitable.
  • Lower maintenance requirements: The absence of moving parts reduces mechanical wear.
  • Flexible system integration: Analog, pulse, relay, and Modbus communication options support different monitoring and control requirements.
  • Wide pipeline compatibility: The specified pipe diameter range accommodates a broad range of installation sizes.
  • Bidirectional flow monitoring: The meter can measure flow in either direction when configured for the application.
  • Convenient data collection: FlowData software supports logging and subsequent analysis of measurement data.
About SSEA

SSEA instruments are Schmierer SEA's own range, offered from Shah Alam and led by pressure gauges. The SRU 25 stainless steel pressure gauge uses a silicon-jelly stabiliser instead of liquid filling and is rated IP66. The STU02 bimetallic thermometer is built to EN 13190. Gauge accessories, flow meters, water quality sensors and calibration tools complete the range.

SSEA instruments by family

FamilySSEA productsStated figures
Pressure gaugesSRU 25, SRU 25X with mini diaphragm seal, SRU 35, SR 01; SRU25 chemical gauges in Hastelloy, Monel and Inconel; SRU15 and SR15 boiler gauges; PCU05 phenolic case gaugeSRU 25: -1 to 100 bar, special versions up to 1,600 bar; 1% fsd with the 100 mm dial
Test pressure gaugesSRU15 test gauge, SFU 15, SF 15250 mm dial
Gauge accessoriesSyphons, cooling tower, snubbers, overload protectors, gauge cocks, shut-off valve, 3-way, 3-valve and 5-valve manifolds, swivel adapter, max drag pointerSee product pages
Electrical pressurePTX-36 gauge transmitter, SSEA-PTIII transmitter, DTG200 digital gaugePTX-36: 4–20 mA, dial still reads in a power failure; DTG200: -1 to 2,500 bar
Pressure calibrationIDTG 100 pressure calibrator, HPCP-700 hydraulic comparison pumpIDTG 100: -1 to 600 bar
TemperatureSTU02 bimetallic and STU01 gas filled thermometers, STW bar-stock thermowellsSTU02 bimetal thermometer to EN 13190
Flow metersCMF VIII Coriolis, MFIII electromagnetic, VFIII vortex, SWFVI swirl, TMFIII thermal mass, OGMFIII oval gear, VAFIII variable area, WMIII, TFLIII and TFGIII turbine, UCOF and UFP-1.0 clamp-on ultrasonicSee product pages
Water qualityDigital sensors for pH, dissolved oxygen, conductivity, turbidity, suspended solids, COD, ammonia nitrogen, nitrate, free chlorine, oil in water, blue-green algae, transparency and colour; MPSX sonde, HMSX handheld meter, MPTX and DCCX controllersSee product pages

How to choose within the range

  • General industrial duty: the SRU 25, all stainless steel with an SS316L tube and socket.
  • Corrosive or viscous media: the SRU 25X with its mini diaphragm seal, or an SRU25 chemical gauge.
  • Pressure testing and reference readings: a 250 mm test gauge, or the DTG200 digital gauge.
  • A reading in the control room: the PTX-36 sends 4–20 mA and keeps its local dial.
  • Temperature on a dial: the STU02 bimetallic or STU01 gas filled thermometer, with an STW thermowell where the stem needs protection.

Service in Shah Alam

Common pressure and temperature gauges are kept in warehouse stock. Our trained technical staff calibrate pressure, temperature and flow instruments in-house and on site. Our diaphragm seal filling station, in Shah Alam since June 2016, assembles seals for gauges, switches and transmitters of any brand.

Send the medium, range and connection and we will match one of our SSEA instruments: send an enquiry. The full gauge line-up is on the pressure gauge page.