Pressure

Bourdon Tube
7 products
Boiler
2 products
Chemical
3 products
Phenolic
1 product
Differential
7 products
Capsule
3 products
Test Pressure Gauge
5 products
Contact
4 products
Diaphragm
3 products
Diaphragm Seal
1 product
Digital
2 products
Pressure Transmitter
10 products
Pressure Switch
5 products
Load and Force
11 products
Accessories
15 products
Temperature

RTD
5 products
Bimetallic
2 products
Gas Filled
2 products
Non-Replaceable Inserts
3 products
Replaceable Inserts
4 products
Ceramic Protection
7 products
Mineral Insulated
4 products
Flameproof and Intrinsically Safe
7 products
Surface and Machinery
30 products
Food and Pharma
7 products
HVAC
9 products
Acids, Alkalis, Salts
4 products
Temperature Switch
1 product
Thermowell
16 products
Indicator, Controller
8 products
Accessories
9 products
Humidity
7 products
Thermocouple
50 products
Cable Sensors
38 products
Head Sensors
9 products
High Temperature
6 products
Temperature Transmitter
6 products
Flow

Electro Magnetic
2 products
Vortex
3 products
Swirl
1 product
Ultrasonic
7 products
Coriolis Mass Flowmeter
28 products
Positive Displacement
6 products
Variable Area
1 product
Differential Pressure
7 products
Turbine
4 products
Flap
1 product
Side Glass
1 product
Thermal gas
5 products
Air Flow/Quality
11 products
Flow Switch
9 products
Flow Computer
3 products
Flow Accessories
2 products
Dosing/Batching
6 products
Level

Radar
3 products
Ultrasonic
1 product
Capacitance
7 products
Conductivity
4 products
Magnetic
1 product
Float/Buoyancy
7 products
Level Indicator
3 products
Vibrating Rod
3 products
Rotary Paddle
2 products
Hydrostatic
2 products
Optical
1 product
Level Switches
11 products
Calibration Devices

Multi Function Calibrators
2 products
Pressure Calibrators
4 products
Temperature Calibrators
6 products
Valve Testing
1 product
Calibration Software
1 product
Valves

Actuator
1 product
Ball Valves
2 products
Butterfly Valves
3 products
Gate Valves
2 products
Globe Valves
3 products
Analytical Sensors

Water Quality Sensors
16 products
Process Systems
11 products
Density and Concentration
12 products
Analytical Controller
2 products
Process Systems
Thermowell
A thermowell is a closed-end tube fixed into the pipe or vessel, so the sensor or dial thermometer inside it can be taken out without draining the line. Schmierer SEA offers its own STW bar-stock range, with wake frequency calculation and exotic alloys available, and offers screw-in, welded and flanged wells and protection tubes from our principal Limatherm.
Which thermowell for which job
The figures below are the ones each product page states; the Limatherm protection tubes and thermowells overview lists tubes for up to 1800 °C.
| Type | Mounting | Material | Stated limits and options |
|---|---|---|---|
| STW1 to STW4 (Schmierer SEA) | Flanged (STW1 straight, STW3 tapered) or 3/8″ to 1″ NPT/BSP male thread (STW2 straight, STW4 tapered) | 316 stainless as standard; carbon steel, 304, 316L, 446; Inconel, Hastelloy C, Monel, titanium, tantalum and more | Solid bar stock, 6 mm tip; hydro test at 100 kg/cm²; Teflon, glass, rubber or tungsten carbide lining or coating |
| SWG, SWS, SWT | Screw-in (SWG), welded (SWS), flanged (SWT) | Steel 1.0460; boiler steel 1.7335, 1.7380; stainless 1.4541, 1.4571, 1.4404 | Bar stock, deep-drilled over the full length, for high pressure and high flow; straight, tapered or stepped |
| OG | Threaded; sensor held by a set screw | Stainless 1.4541 | G1/4 to G3/4 or M14x1.5 to M27x2; 6 to 14 mm; max 800 °C |
| OGG | Male thread | Stainless 1.4541 | 6 to 14 mm; max 800 °C |
| OSG | Welded | Stainless 1.4541 | Length 50 to 2000 mm |
| OTG | Flange DN20 PN16 | Stainless 1.4541 | See product page |
| OS1 and OS2 tubes | Replaceable tube | Stainless 1.4541 | 4 to 15 mm; max 800 °C in air |
| OS3 tube | Replaceable tube | Heat-resistant 1.4841, creep-resistant 1.4762, 15Cr25Ti | DN20, DN22; up to 1150, 1200 and 1100 °C by material |
| OS4 tube | Replaceable tube | Stainless 1.4541 | 16 and 20 mm |
| OC ceramic tube | Replaceable tube | Mullite 610, corundum 799 or monocrystal SAP | 5 to 24 mm; for high operating temperatures |
How to choose a thermowell
- Pressure and velocity: fast or high pressure flow calls for a well drilled from solid bar, the STW or SW types; on the STW range a wake frequency calculation to ASME PTC 19.3 can be ordered.
- Mounting: screw-in (STW2, STW4, SWG, OG, OGG), welded (SWS, OSG) or flanged (STW1, STW3, SWT, OTG), to match the branch on the line.
- Medium: 316 stainless is the STW standard; for acids, the STW range comes in Hastelloy C or tantalum, or with a glass or Teflon lining.
- Heat: above the 800 °C of the 1.4541 tubes, choose OS3 in heat-resistant or creep-resistant steel, or a ceramic OC tube.
- Length and fit: STW insertion depth, lagging length and tip diameters are made to suit the line size; give us the sensor diameter so the bore fits it.
- What goes inside: the STW range takes RTDs, thermocouples and bimetal dial thermometers, with instrument threads from 1/4″ to 1″ BSP or NPT, or M20.
For furnaces, kilns and flue gases, where there is little pressure, see our protection tube guide.
Service in Shah Alam
A sensor in a well can be drawn out for calibration while the line stays under pressure. Our trained and qualified technical staff calibrate temperature instruments in-house at our Shah Alam service centre and on site.
Send us the process connection, pressure, temperature, medium and the sensor you will fit: send an enquiry. For the instrument that goes inside, see bimetallic thermometers and thermocouples.






