Plugs and Sockets

Plugs and socket are components of measuring systems used for connection of temperature sensors with a measuring device such as controller, temperature indicator or recorder. They are also used for connections and extensions measuring lines.

2 People watching this product now!
Description

Description

Plug STD-W-…* | Socket STD-G-…*
– standard plug and socket for thermocouple sensors
– operating temperature: -20÷200ºC
– lead wire diameter max: 8 mm
– thermocouple type: J, K, N, R, S, T, B, E

* required type of thermocouple

Plug STDC-W-…* | Socket STDC-G-…*
– ceramic plug and socket for thermocouple sensors
– operating temperature: 0÷650°C
– lead wire diameter max: 8 mm
– thermocouple type: J, K, N, R, S, T, B, E

* required type of thermocouple

Plug STD3-W-…* | Socket STD3-G-…*
– standard plug and socket for thermocouple sensors
– operating temperature: -20÷200°C
– lead wire diameter max: 8 mm
– for RTD resistors

* 2 or 3-wire line

Plug MIN3-W-…* | Socket MIN3-G-…*
– miniature plug and socket for RTD sensors
– operating temperature: -20÷200ºC
– lead wire diameter max: 4,5 mm
– for RTD resistors

* 2 or 3-wire line

Plug MINC-W-…* | Socket MINC-G-…*
– plug and socket for thermocouple sensors
– operating temperature: 0÷650°C
– lead wire diameter max: 4,5 mm
– thermocouple type: J, K, N, R, S, T, B, E

* required type of thermocouple

Plug MIN-W-…* | Socket MIN-G-…*
– miniature plug and socket for thermocouple sensors
– operating temperature: -20÷200ºC
– lead wire diameter max: 4,5 mm
– thermocouple type: J, K, N, R, S, T, B, E

* required type of thermocouple

Plug FFA….* | Socket PCA….*
– LEMO plug and socket
– operating temperature: -50÷250ºC
– lead wire diameter max: 4,4 mm (0S),
6,7 mm (1S),
8,5 mm (2S),
10,5 mm (3S)
– apply to thermocouples and RTDs

* required type: 0S, 1S, 2S or 3S

About Limatherm

Products & Features

Limatherm specializes in industrial temperature measurement and control solutions. Core Products & Services are 

  • Temperature Sensors: wired and head sensors, mineral-insulated (sheathed) RTD and Thermocouples
  • Hazardous Area Solutions: intrinsically safe (Exia) and flameproof (Exd) 
  • Accredited Laboratory: acc. to ISO/IEC 17025 standard
  • High-Temperature Patent:  up to 2300°C
  • Material Diversity: acid-resistant steel, borosilicate glass, ceramics (e.g., Hexoloy)

Key Benefits

  • Reliability in Extreme Environments: Suitable for high-temperature and harsh conditions (e.g., molten metal, acidic environments).
  • Adaptability: Suitable for diverse industries such as metallurgy, chemical processing, and food production.
  • Easy Installation: Features like replaceable inserts and flexible mineral-insulated cables reduce maintenance time and cost.