Platinum-Coated Ceramic Tube High-Temperature Thermocouples

Measure extreme furnace temperatures up to +1700°C with superior chemical resistance. Therefore, glass manufacturers and metallurgical plants rely on Limatherm TTSC-ACT, TTBC-ACT, and TTRC-ACT thermocouples. Specifically, they deploy these probes for continuous high-heat tracking. Because these sensors combine dense Corundum C799 ceramic tubes with a platinum-rhodium protective coat, they resist molten glass. Furthermore, they block corrosive alkaline vapors. Consequently, your facility prevents premature sensor failure. As a result, you maintain accurate thermal control across harsh production lines.

SKU: TTSC-ACT, TTBC-ACT, TTRC-ACT Categories: , , ,
Description

Description

Product Types

The TTSC-ACT, TTBC-ACT, and TTRC-ACT platform maps into three noble-metal configurations. Thus, you can match your exact furnace temperature limits:

  • TTSC-ACT (Type S – PtRh10-Pt): Uses a 10% rhodium-platinum alloy element per EN 60584. Therefore, it provides continuous precision monitoring up to +1600°C.
  • TTRC-ACT (Type R – PtRh13-Pt): Features a 13% rhodium-platinum alloy core. Consequently, it delivers higher thermoelectric output and stability up to +1600°C.
  • TTBC-ACT (Type B – PtRh30-PtRh6): Built with a 30% / 6% rhodium-platinum junction. Thus, it handles ultra-high temperatures up to +1700°C continuous (+1800°C peak).

Working Principle

The sensor operates continuously using platinum-rhodium junctions inside a platinum-coated Corundum C799 tube. First, the outer platinum-rhodium layer acts as a non-reactive barrier. As a result, it blocks molten glass, alkali vapors, and corrosive gases. Next, heat transfers cleanly through the platinum coat and dense ceramic wall. Thus, the internal noble-metal junction captures extreme temperature shifts instantly. Furthermore, the thermocouple generates a precise millivolt signal. Finally, the terminal block or transmitter inside the Type AA head routes this signal cleanly to your control system.

Key Specs

Technical Parameter Manufacturer Specification
Noble-Metal Elements Type S (TTSC-ACT), Type R (TTRC-ACT), Type B (TTBC-ACT) per EN 60584-1
Temperature Range 0°C to +1600°C (Type S/R) / +600°C to +1700°C continuous (+1800°C peak)
Protection Tube Alumina Corundum C799 (99.7% Al₂O₃) with outer Platinum-Rhodium (PtRh) coat
Outer Diameters 10 mm, 12 mm, 15 mm, or 20 mm coated ceramic tubes with metallic neck
Connection Head Heavy-duty cast aluminum Type AA head with M20x1.5 cable entry
Accuracy Class Conforms strictly to EN 60584-1 Class 1 or Class 2 tolerances

Product Models & Functional Configurations

The Limatherm TTSC-ACT, TTBC-ACT, and TTRC-ACT catalog offers tailored constructions. Moreover, it includes verified factory electronics options:

  • Custom PtRh Coated Lengths: Manufactured with tailored coating coverage. Therefore, it shields the exact immersion zone exposed to molten glass or corrosive vapors.
  • Single or Double Tube Build: Available with a single coated sheath or a double-tube assembly. Consequently, the inner ceramic sheath maximizes gas tightness and mechanical strength.
  • Mounting Flanges & Necks: Paired with steel holding tubes, sliding flanges, or threaded bushings. Thus, technicians set exact furnace wall immersion depths cleanly.
  • Terminal Block or AP Transmitter: Equipped with a porcelain block for direct wiring, or an AP / LTT head transmitter. As a result, it converts signals to 4–20 mA or HART inside the Type AA head.

Advantages

  • Superior Chemical & Glass Resistance: The outer platinum-rhodium coat stops alkali vapors and molten glass from dissolving the ceramic tube. As a result, your sensor survives far longer than bare ceramic probes.
  • Extreme Heat Endurance up to +1700°C: Noble-metal elements and Corundum C799 sheaths operate continuously in extreme firing zones. Therefore, your facility maintains precise control without frequent replacements.
  • Zero Thermoelement Poisoning: Gas-tight Corundum walls and the noble-metal barrier block reducing gases completely. Consequently, you prevent calibration drift and ensure consistent product quality.
  • Spacious Type AA Connection Head: The robust aluminum housing offers ample internal clearance. Thus, technicians install double-element blocks or 4–20 mA transmitters effortlessly.

Applications

Process engineers integrate Limatherm TTSC-ACT, TTBC-ACT, and TTRC-ACT thermocouples across extreme furnace environments:

  • Glass Melting Tanks & Forehearths: Monitors molten glass bath, throat, and crown temperatures continuously. Moreover, it prevents the rapid erosion common to bare ceramic tubes.
  • Fiberglass & Mineral Wool Bushings: Tracks high-temperature feeder channels and spinning zones reliably. As a result, sensors endure aggressive vapor exposure without drift.
  • High-Temperature Ceramic Kilns: Supervises sintering and firing zones up to +1700°C. Therefore, corrosive kiln atmospheres do not degrade the outer sheath.
  • Metallurgical & Chemical Reactors: Delivers drift-free feedback inside high-heat reactors, incinerators, and slag chambers.
About Limatherm

Products & Features

Limatherm specializes in industrial temperature measurement and control solutions. Core Products & Services are 

  • Temperature Sensors: wired and head sensors, mineral-insulated (sheathed) RTD and Thermocouples
  • Hazardous Area Solutions: intrinsically safe (Exia) and flameproof (Exd) 
  • Accredited Laboratory: acc. to ISO/IEC 17025 standard
  • High-Temperature Patent:  up to 2300°C
  • Material Diversity: acid-resistant steel, borosilicate glass, ceramics (e.g., Hexoloy)

Key Benefits

  • Reliability in Extreme Environments: Suitable for high-temperature and harsh conditions (e.g., molten metal, acidic environments).
  • Adaptability: Suitable for diverse industries such as metallurgy, chemical processing, and food production.
  • Easy Installation: Features like replaceable inserts and flexible mineral-insulated cables reduce maintenance time and cost.