ADLM-P Bubbling-Through Pressure Transducer

The Müller IE ADLM-P Bubbling-Through Pressure Transducer provides reliable, continuous liquid-level measurement using the air-bubbling principle. It measures the hydrostatic pressure required to release air bubbles from a submerged tube. As a result, the system can monitor liquid levels without directly immersing the pressure transducer in the process liquid.

Moreover, the ADLM-P is suitable for aggressive and abrasive media. Its flexible installation concept also allows the bubbling point to be located up to 50 metres from the transducer, making it useful for demanding industrial level-measurement applications.

SKU: ADLM-P-1 Categories: , Tag:
Description

Description

Models and Configurations

  • ADLM-P: Standard bubbling-through pressure transducer.
  • ADLM-PV: Bubbling-through pressure transducer with a valve.

The ADLM-PV provides an alternative configuration with a valve. Confirm the required version and accessories with the manufacturer before ordering.

Key Specifications

  • Manufacturer: Müller Industrie-Elektronik
  • Model: ADLM-P
  • Measurement principle: Bubbling-through air purge and hydrostatic pressure
  • Pressure type: Positive relative pressure
  • Measuring ranges: 0–50 mbar, 0–100 mbar, 0–200 mbar, 0–350 mbar and 0–1000 mbar
  • Output signals: 4–20 mA and 0–10 V
  • Supply voltage: 24 VDC ±20%
  • Accuracy: Up to ±1% of full-scale value
  • Maximum distance to bubbling point: 50 m
  • Liquid compatibility: Suitable for a wide range of liquids, including aggressive and abrasive media, subject to installation and material compatibility
  • Pressure connection: For 6 mm plastic tubing, according to the product documentation
  • Protection rating: IP65, as specified in the published product documentation

Working Principle

The ADLM-P uses the pressure needed to push air through a tube submerged in the liquid.

  1. Air is supplied: A suitable air supply feeds the bubbling tube through the pressure-measurement system.
  2. The tube reaches the liquid: The open end of the tube is installed at the desired measurement point below the liquid surface.
  3. Air bubbles escape: Air pressure rises until it overcomes the hydrostatic pressure at the tube outlet, allowing bubbles to emerge.
  4. Pressure is measured: The ADLM-P measures the required positive relative pressure. This pressure corresponds to the liquid height above the bubbling point.
  5. The output signal is transmitted: The transducer converts the pressure measurement into a 4–20 mA or 0–10 V signal for a compatible PLC, DCS, indicator, or control system.

The relationship between pressure and liquid height is:

h = p / (ρg)

Here, h is the liquid height above the bubbling point, p is the measured hydrostatic pressure, ρ is the liquid density, and g is gravitational acceleration.

Therefore, accurate level calculation depends on knowing the liquid density and correctly positioning the bubbling tube.

Main Advantages

  • No direct sensor contact with the liquid: The pressure transducer remains outside the process liquid.
  • Suitable for demanding media: The method can be useful for aggressive, abrasive, or contaminated liquids when the tube and other wetted components are compatible.
  • Continuous level monitoring: Provides an analogue signal for ongoing process monitoring.
  • Flexible installation: The bubbling point can be located up to 50 m from the transducer.
  • Two analogue output options: Choose between 4–20 mA and 0–10 V according to the system configuration.
  • Foam-tolerant measurement principle: Unlike ultrasonic level measurement, the system measures pressure at the submerged tube outlet rather than relying on an echo from the liquid surface.
  • Practical retrofit option: Bubbling-through measurement can be useful where direct-contact probes or more complex level instruments are unsuitable.

Typical Applications

The ADLM-P can be used in:

  • Wastewater treatment plants
  • Pumping stations and pump houses
  • Water storage tanks and reservoirs
  • Chemical-processing systems
  • Biogas plant liquid-level monitoring
  • Water and fuel tanks in special-purpose vehicles
  • Industrial liquid-level monitoring where direct sensor immersion is undesirable

Installation and Selection Considerations

First, select the pressure range according to the maximum liquid height and density. A range that is too high can reduce measurement resolution, while an undersized range may expose the instrument to excessive pressure.

In addition, ensure that the air supply, pressure connections, joints, and bubbling tube are correctly installed and free from leakage. The tube outlet should be positioned at the intended measurement point, and the manufacturer’s recommended outlet geometry should be followed.

Finally, consider the need for a stable air supply, the potential for tube blockage, and the compatibility of all materials with the liquid. The ADLM-P requires a suitable air-purge arrangement; it is not a standalone immersed probe.

Conclusion

The Müller IE ADLM-P is a practical solution for continuous liquid-level measurement using the bubbling-through principle. By measuring the pressure required to release air from a submerged tube, it avoids direct immersion of the electronic pressure sensor. Consequently, it is particularly useful for selected aggressive, abrasive, or contaminated-liquid applications.

About Muller IE

Products & Features

Müller Industrie Elektronik GmbH from Germany is specializing in modular and compact sensors for customized hardware and electronic solutions, IO Link, digital displays, OEM manufacturing, digital displays, product certifications, etc.

  • Sensors & Transmitters: Temperature, Force, Pressure, Level, Flow, Humidity, and Inclination measurement.
  • MI-Series (Modular Inline Sensors): High-density, miniature housing designed for, restricted spaces in machinery, plant engineering, and vehicle construction.
  • Digital Indicators
  • OEM Electronics & IO-Link: Customized, low-cost sensor boards and IO-Link-capable products for industrial automation.
  • Safety Technology: SMM-HD-SIL1-IO: Strain gauge bridge measuring amplifier with SIL1/PLc safety

Key Benefits

  • Broad Sensor Portfolio
  • Modular Product Design
  • Robust & Certified Technology: IECEx, EHEDG, SIL3, TÜV-certified
  • Advanced Digital Indicators: full graphic TFT (LCD) displays and universal measuring instruments
  • In-house Development & Production: made in Germany