PSV Pressure Safety Valve Testing and Calibration Work Station

The Presys PSV Valve Test Workstation, available from Schmierer SEA Malaysia, is a digital testing system designed to inspect, test, and calibrate pressure safety valves (PSVs) and pressure relief valves (PRVs). It helps technicians verify the pressure at which a valve opens and the pressure at which it reseats, supporting reliable pressure protection in industrial systems.

The workstation combines a controlled pressure supply, digital pressure measurement, a valve mounting system, and automated test-data acquisition. It can automatically register the valve’s opening pressure, also known as the set pressure or POP, and its reseating pressure. In addition, compatible Isoplan® calibration software can record test results and generate documented calibration reports.

The system is suitable for maintenance workshops and industrial facilities that require repeatable valve testing, traceable records, and improved control over pressure-relief device maintenance.

SKU: PSV portable Category:
Description

Description

Key Features of the Presys PSV Valve Test Workstation

psv test and calibration workstation for pressure safety valves

  • Automatic pressure detection: The workstation records the valve’s opening pressure and reseating pressure during testing.
  • Digital pressure measurement: Technicians can monitor pressure readings and document valve performance throughout the test.
  • Flexible valve connections: Depending on the configuration, the workstation accommodates threaded and flanged valves.
  • Seat leakage testing: A bubble counter and suitable adapters help technicians check valve seat leakage.
  • Operator protection: A protective polycarbonate shield helps separate the operator from the test area.
  • Digital test reports: Compatible Isoplan® software stores test data and supports report generation.
  • Configurable pressure ranges: Presys offers different configurations to meet specific valve testing requirements.

How Does the Presys PSV Valve Test Workstation Work?

PSV calibration certificate

The workstation follows a controlled testing process to evaluate the performance of pressure safety and relief valves.

1. Mount the Valve

First, the technician secures the PSV to the workstation using suitable adapters and the appropriate clamping arrangement. This step helps ensure a stable setup before testing begins.

2. Apply Test Pressure

Next, the workstation applies a controlled pressure using a compatible test medium. Depending on the model and application, technicians may use air, nitrogen, water, or oil.

3. Measure the Opening Pressure

As the pressure increases, the valve eventually opens at its set pressure. The digital acquisition system records this opening point, allowing the technician to compare the result with the required setting.

4. Check Reseating Pressure and Leakage

After the valve opens, the technician monitors its closing behaviour as the pressure decreases. The workstation records the reseating pressure, while suitable accessories help check seat leakage. These results provide additional information about valve performance.

5. Record Results and Generate Reports

Finally, compatible Isoplan® software helps technicians store test results and generate reports. Therefore, maintenance teams can review historical performance, document servicing activities, and improve traceability.

Technical Specifications

Parameter Description
Equipment type Digital PSV/PRV test workstation
Valve connections Threaded and flanged, depending on configuration
Pressure measurement Digital measurement and automatic pressure registration
Test functions Opening pressure, reseating pressure, and seat leakage checks, where configured
Safety features Protective shield
Software Compatible Isoplan® software, depending on configuration
Installation options Workstation or selected skid-mounted arrangements

Note: Maximum test pressure, supported valve sizes, test media, and available software functions depend on the specific model. Always confirm the manufacturer’s datasheet before selecting a workstation.

Industrial Applications

The Presys PSV Valve Test Workstation supports several industrial maintenance activities:

  • Oil and gas: Test pressure safety valves used in production facilities, refineries, and gas-processing plants.
  • Petrochemical plants: Verify the opening and reseating performance of relief valves.
  • Power generation: Support maintenance of safety valves in steam and utility systems.
  • Industrial workshops: Test valves after inspection, repair, or servicing.
  • Calibration laboratories: Maintain documented test results and improve traceability.

In each application, technicians should follow the applicable testing procedures and valve manufacturer’s requirements.

Benefits of the Presys PSV Valve Test Workstation

The workstation improves testing consistency by combining controlled pressure application with digital measurement. In addition, automatic data acquisition reduces manual recording and helps technicians document results more efficiently.

Furthermore, compatible reporting software supports traceability and maintenance planning. The protective shield also adds a safety measure during testing. However, technicians must still follow the workstation’s operating instructions and appropriate pressure-testing safety procedures.

About Presys

Key Benefits

  • Multifunctional & Integrated Design
  • High Accuracy & Stability
  • Advanced Automation & Documenting
  • Advanced Communication

Products & Features

Presys specializes in a wide range of calibration equipment and software solutions for pressure, temperature, and electrical signals as well as PSV valve workstations. Presys maintains its own laboratory to guarantee traceability to international standards (SI). Many Presys devices include HART protocol support, built-in PDF viewers, and the ability to generate reports directly from the device via Wi-Fi or USB.

  • Temperature Calibrators: dry block and liquid bath, -60 °C to 1200 °C. 
  • Pressure Calibrators: automatic - intrinsically safe - compact
  • Universal Process Calibrators: accuracy up to 0.01% FS - intrinsically safe
  • Mobile Calibration workstations for pressure safety/relief valves (PSV) - compact, transportable, automated digital registration of critical testpoints, 1/2” to 10”, up to 700 bar
  • Smart Connectivity: Compatible with HART, Profibus, USB, Internet, integration with SAP, Azur, Oracle, SQL
  • Calibration Software: calibration automation and management system that centralizes data, schedules calibrations, and issues certificates.